1991
DOI: 10.1177/107110079101200304
|View full text |Cite
|
Sign up to set email alerts
|

The Use of a Grommet Bone Liner for Flexible Hinge Implant Arthroplasty of the Great Toe

Abstract: Press-fit titanium grommets were developed to shield flexible hinged silicone implants used for arthroplasty of the radiocarpal, metacarpophalangeal, and metatarsophalangeal joints. Since 1985, 179 titanium circumferential grommets were used in 90 first metatarsophalangeal joints with excellent, pain-free, functional results and favorable bone response around the implant stems and at the bone-grommet interface. There were no complications due to particulate reactivity, implant fracture, or grommet fracture. Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
17
0
1

Year Published

1998
1998
2014
2014

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 57 publications
(18 citation statements)
references
References 6 publications
0
17
0
1
Order By: Relevance
“…5 In a study using implants with or without titanium grommets, results were excellent in 90 feet (66 had RA) after a mean of 29 months. 6,8 There was no evidence of silicone synovitis, bone resorption, or implant fracture; only 2 implants rotated and required revision. 6,8 In a case report examining the bone/implant interfaces, silicone particles within the fibrous tissue, and a tear and severe scuffing of the implant surface were detected in the joint without grommets (but not in the joint with grommets.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…5 In a study using implants with or without titanium grommets, results were excellent in 90 feet (66 had RA) after a mean of 29 months. 6,8 There was no evidence of silicone synovitis, bone resorption, or implant fracture; only 2 implants rotated and required revision. 6,8 In a case report examining the bone/implant interfaces, silicone particles within the fibrous tissue, and a tear and severe scuffing of the implant surface were detected in the joint without grommets (but not in the joint with grommets.…”
Section: Discussionmentioning
confidence: 99%
“…6,8 There was no evidence of silicone synovitis, bone resorption, or implant fracture; only 2 implants rotated and required revision. 6,8 In a case report examining the bone/implant interfaces, silicone particles within the fibrous tissue, and a tear and severe scuffing of the implant surface were detected in the joint without grommets (but not in the joint with grommets. 16 Grommets may improve implant durability and prevent particulate synovitis.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Titanium metal grommets were introduced in 1987 for MCP joint arthroplasty and theoretically protect the silicone implant from fracture and fragmentation [15,16,18,[20][21][22]. We found two reports of particulate metal debris associated with silicone implants with grommets leading to a robust tissue reaction [9,25].…”
Section: Introductionmentioning
confidence: 99%