1983
DOI: 10.1016/0021-9290(83)90186-0
|View full text |Cite
|
Sign up to set email alerts
|

The two-burst pattern revisited

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

1984
1984
2002
2002

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…To quantify the force production in the muscles during the stimulation protocols, we implanted force transducers acutely on the distal tendons of both soleus muscles approximately 2 weeks after surgery and again about 1 week before the terminal experiment. Each force transducer consisted of an oval, stainless steel buckle; a standard semiconductor strain gauge bonded on 1 side of the element and configured in a Wheatstone bridge; and a removable center bar placed across the oval piece for securing the tendon 39. Forces were recorded first during passive manipulation of the limb through the simulated step cycle and then for approximately 5–10 min under the stimulation conditions for each cat.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…To quantify the force production in the muscles during the stimulation protocols, we implanted force transducers acutely on the distal tendons of both soleus muscles approximately 2 weeks after surgery and again about 1 week before the terminal experiment. Each force transducer consisted of an oval, stainless steel buckle; a standard semiconductor strain gauge bonded on 1 side of the element and configured in a Wheatstone bridge; and a removable center bar placed across the oval piece for securing the tendon 39. Forces were recorded first during passive manipulation of the limb through the simulated step cycle and then for approximately 5–10 min under the stimulation conditions for each cat.…”
Section: Methodsmentioning
confidence: 99%
“…Forces were recorded first during passive manipulation of the limb through the simulated step cycle and then for approximately 5–10 min under the stimulation conditions for each cat. The force transducers were calibrated statically (by the hanging of known weights) before implantation and dynamically during the in situ testing of the mechanical properties of the soleus (see Sherif et al39 for details). The force data were analyzed on a computer with in‐house software.…”
Section: Methodsmentioning
confidence: 99%