8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227)
DOI: 10.1109/ichqp.1998.759919
|View full text |Cite
|
Sign up to set email alerts
|

The transient and steady state performance of a shunt active filter using measured site data

Abstract: Abstract-This paper presents the analysis of real power system events recorded at a light industrial site to determine the effect of a shunt active filter on power quality. The shunt active filter is shown to improve power quality by lowering the distortion of the supply voltage in both the transient and steady state. The shunt active filter power rating and other design information are also determined. The performance degradation of the shunt active filter when it has a limited rating is then demonstrated. In… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…These voltages and currents are transformed into orthogonal frame which can be expressed as positive, negative, and zero sequences by (6) …”
Section: Shunt Active Filtermentioning
confidence: 99%
See 1 more Smart Citation
“…These voltages and currents are transformed into orthogonal frame which can be expressed as positive, negative, and zero sequences by (6) …”
Section: Shunt Active Filtermentioning
confidence: 99%
“…The operation principle of an active filter is based on PWM or SVM three-phase inverter to generate nonsinusoidal currents to meet harmonic current requirement of the nonlinear load. Many various configurations, control strategies, and applications of active filters are offered in the literature [5][6][7]. The SAF performs the filtering action by injecting harmonic components which cancel those from the load, thereby the line current becomes free of harmonics [8].…”
Section: Introductionmentioning
confidence: 99%
“…In [7] and [8], different aspects of transient response of some active filters are studied to insure instantaneous ability of such theories. Even, results of some simulations have been described in [9], where different methods for instantaneous compensations are simulated and discussed to insure an adequate compensation of harmonics when using these theories.…”
Section: Instantaneous Power Theorymentioning
confidence: 99%
“…Fig. 12 shows that the magnitude reached by the phase to ground voltage in DS3 during transient was = 2 p.u.. Then, this requirement should be taken into account when designing the active filter [4].…”
Section: B Transients Statementioning
confidence: 99%