2018
DOI: 10.1016/j.jtcvs.2017.08.099
|View full text |Cite
|
Sign up to set email alerts
|

The tip of the iceberg: Evaluating the mechanism behind dehiscence of mitral annuloplasty rings

Abstract: Mitral annuloplasty ring. Central Message Surgeons are not the only factor in the dehiscence of mitral annuloplasty rings. Additional forces acting upon the sutures are ring type, ring sizing, suture position, and left ventricular pressure.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 5 publications
(7 reference statements)
0
2
0
Order By: Relevance
“…Annuloplasty alone only offers a solution for annular tethering while not fully addressing the ventricular aspect, therefore being associated with worsening and recurrent MR [ 50 , 51 ]. The weakened and calcified annular tissue found in ischaemic mitral regurgitation together with more aggressive annular downsizing contributes to creating a clinical picture that exposes the annulus-ring system to greater stresses, thus increasing the risk of dehiscence [ 3 , 50 , 51 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Annuloplasty alone only offers a solution for annular tethering while not fully addressing the ventricular aspect, therefore being associated with worsening and recurrent MR [ 50 , 51 ]. The weakened and calcified annular tissue found in ischaemic mitral regurgitation together with more aggressive annular downsizing contributes to creating a clinical picture that exposes the annulus-ring system to greater stresses, thus increasing the risk of dehiscence [ 3 , 50 , 51 ].…”
Section: Discussionmentioning
confidence: 99%
“…Dehiscence eliminates the annular tension required for adequate leaflet coaptation and results in haemodynamic compromise, usually diagnosed using echocardiography. Whilst the true incidence of ring dehiscence in annuloplasty-based valve repair remains elusive and disputed, evidently, it is a pressing concern that contributes to a significant portion of surgical failures and subsequent reoperation [ 2 , 3 ]. Particularly for annuloplasty-based mitral repair, 13–42% of postoperative procedural failures has been attributed to ring dehiscence, presenting an epidemiological disparity too great to ignore [ 3 ].…”
Section: Introductionmentioning
confidence: 99%