The time-distance recorder as a means of improving the accuracy of fetal blood flow measurements

Abstract: The influence of pulsatile diameter changes on calculation of volume flow has been studied. In vitro studies and an animal study were carried out with a real-time imaging and pulsed Doppler velocity measurement system. For precise pulsatile diameter information a wall motion tracking device was incorporated. Whereas in vitro a high degree of accuracy was found for the measurements of volume flow, this could not be substantiated in the descending aorta of the fetal lamb, in which Doppler volume flow differed be… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1988
1988
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Requiring users to repeat measurements multiple times minimized error associated with any cyclic variation in vessel diameter. 26,27 …”
Section: Discussionmentioning
confidence: 99%
“…Requiring users to repeat measurements multiple times minimized error associated with any cyclic variation in vessel diameter. 26,27 …”
Section: Discussionmentioning
confidence: 99%
“…A 'frozen' picture of the vessel is obtained on the screen and the diameter is measured from one intimal surface to the other using callipers. The vessel diameter was taken as the mean of five separate readings (Struyk, Pipers, Wladimiroff, Lotgering, Tonge & Bom, 1985). All measurements were taken at least 3 cm away from the bifurcation in order to reduce 17S l-ity I'A L' RICISE AM) 1,1\11i llAf--\I()I))AAM1('S interference from turbulence, although theoretically time-averaged mean velocity makes no assumption of flow profile (Evans, McDicken, Skidmore & Woodcock, 1989).…”
Section: Blood Flowmentioning
confidence: 99%
“…A 'frozen' picture of the vessel is obtained on the screen and the diameter is measured from one intimal surface to the other using callipers. The vessel diameter was taken as the mean of five separate readings (Struyk, Pipers, Wladimiroff, Lotgering, Tonge & Bom, 1985). All measurements were taken at least 3 cm away from the bifurcation in order to reduce 17S …”
Section: Blood Flowmentioning
confidence: 99%
“…The diameter of the portal vein depends on respiration, and, therefore, the diameter of the PV was measured under respiratory suspension during expiration. Despite numerous methods described in the literature for determining a mean vessel diameter to account for caliber fluctuations over time, the authors of this study did not see any relevant pulsatility in either AHC or AHP [15,16].…”
Section: Determination Of Vessel Diametermentioning
confidence: 54%
“…determining a mean vessel diameter to account for caliber fluctuations over time, the authors of this study did not see any relevant pulsatility in either AHC or AHP [15,16]. The insonation angle refers to the angle between the vessel to be measured and the transducer.…”
Section: Location Of the Probe Insonation Angle And Doppler Windowmentioning
confidence: 90%