1931
DOI: 10.1098/rspa.1931.0183
|View full text |Cite
|
Sign up to set email alerts
|

The thermal conductivities of the saturated hydrocarbons in the gaseous state

Abstract: Downloaded from iodides used in the preparation of the hydrocarbons were carefully purified by repeated fractionation, and the following are the boiling points of the specimens used.Methyl

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
5
0

Year Published

1960
1960
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 33 publications
(7 citation statements)
references
References 0 publications
2
5
0
Order By: Relevance
“…The maximum deviation of the literature data is about 15% at temperatures from 340 K and 380 K. The deviations of the present measurements and the literature data from eq 5 are presented in Figure 4. Good agreement is found between the present steady-state measurements and the steady-state measurements of Nieuwoudt et al, 2 Mann and Dickins, 15 Lambert et al, 16 and Kazaryan and Ryabtsev. 18 The dilute-vapor data of Parkinson and Gray 17 and Heinemann et al 19 exhibit strong deviations at increasing temperatures.…”
Section: Correlation Developmentsupporting
confidence: 83%
“…The maximum deviation of the literature data is about 15% at temperatures from 340 K and 380 K. The deviations of the present measurements and the literature data from eq 5 are presented in Figure 4. Good agreement is found between the present steady-state measurements and the steady-state measurements of Nieuwoudt et al, 2 Mann and Dickins, 15 Lambert et al, 16 and Kazaryan and Ryabtsev. 18 The dilute-vapor data of Parkinson and Gray 17 and Heinemann et al 19 exhibit strong deviations at increasing temperatures.…”
Section: Correlation Developmentsupporting
confidence: 83%
“…In Figure , the calculated thermal conductivity values are compared with most of the available experimental data, the correlations of Hendl et al and Friend et al, and the values for the unadjusted PES. It can be seen that many of the data sets are not mutually consistent within their claimed uncertainties (if uncertainties are provided at all), making it difficult to assess the quality of the calculated values.…”
Section: Resultsmentioning
confidence: 99%
“…6, the thermal conductivity values obtained using the adjusted potential function, λ adj , are compared with those obtained using the unadjusted one, λ unadj , with a large number of experimental data sets, [63][64][65][66][67][68][69][70][71][72][73][74][75] with the zero-density part of the correlation of Marsh et al, 74 and with the recommended reference values of Younglove and Ely. 76 We extrapolated the data of Zheng et al 72 at 323.75 K and the steady-state hot-wire data of Marsh et al 74 to zero pressure.…”
Section: B Resultsmentioning
confidence: 99%