The test equation method for linear state estimation based on PMU data

Abstract: The advent of next generation devices for synchronized phasor measurements (voltage and current values in lines) -PMU-makes it possible to realize linear algorithms of state estimation. The paper suggests the development of the test equation technique for linear state estimation of power system facilities that are monitored on the basis of PMU measurements. New algorithms for the construction of the test equations on the basis of PMU measurements are presented. The algorithms are based on the exclusion of unme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…For the SE PCS to operate under the WAMS conditions, used is a traditional algorithm of the linear state estimation through the state vector in rectangular coordinates [2]. Also, solving linear SE is successfully realized via the test equation method developed at the Melentiev Energy Systems Institute of the Siberian Branch of the Russian Academy of Sciences [3,4] that has a number of advantages over the traditional nonlinear approach [5], the main of them being a possibility to a-priori detect bad data (BD).…”
Section: Block Diagram Of Se Pcs For the Reliability Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…For the SE PCS to operate under the WAMS conditions, used is a traditional algorithm of the linear state estimation through the state vector in rectangular coordinates [2]. Also, solving linear SE is successfully realized via the test equation method developed at the Melentiev Energy Systems Institute of the Siberian Branch of the Russian Academy of Sciences [3,4] that has a number of advantages over the traditional nonlinear approach [5], the main of them being a possibility to a-priori detect bad data (BD).…”
Section: Block Diagram Of Se Pcs For the Reliability Analysismentioning
confidence: 99%
“…Also, solving linear SE is successfully realized via the test equation method developed at the Melentiev Energy Systems Institute of the Siberian Branch of the Russian Academy of Sciences [3,4] that has a number of advantages over the traditional nonlinear approach [5], the main of them being a possibility to a-priori detect bad data (BD).…”
Section: Block Diagram Of Se Pcs For the Reliability Analysismentioning
confidence: 99%