2015
DOI: 10.1016/j.nucengdes.2014.11.045
|View full text |Cite
|
Sign up to set email alerts
|

The TALL-3D facility design and commissioning tests for validation of coupled STH and CFD codes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…were benchmarked to evaluate their extended function for lead/lead‐bismuth system 7‐9,39 . Later, with the purpose to validate multidimensional CFD/STH codes, a third leg with a 3D test section was added to the original TALL facility 41 . More detailed information of TALL and TALL‐3D design can be seen in References 7, 8, 39–41.…”
Section: Benchmarking Of Lethac With Tall Facilitymentioning
confidence: 99%
“…were benchmarked to evaluate their extended function for lead/lead‐bismuth system 7‐9,39 . Later, with the purpose to validate multidimensional CFD/STH codes, a third leg with a 3D test section was added to the original TALL facility 41 . More detailed information of TALL and TALL‐3D design can be seen in References 7, 8, 39–41.…”
Section: Benchmarking Of Lethac With Tall Facilitymentioning
confidence: 99%
“…In contrast, the ability of CFD to simulate geometrical effects directly makes it easier to argue that experiments performed for other designs (and thus in different geometrical configurations) will provide a useful contribution for validating the new tool. Thanks to these arguments, multi-scale/CFD tool may thus rely on a growing experimental database for validating coupled effects: for the effect of pool thermal-hydraulics on natural convection, TALL-3D [25] (SET), CIRCE-HERO [26] (IET) and E-SCAPE [27] (IET) may be considered; for the effect of inter-wrapper flow on S/A cooling, THEADES [28] (SET), PLANDTL-1 [29] (IET) and PLANDTL-2 [30] (IET) are available or will be in the near future; -CLEAR-S [31] (IET) will present an interesting case where it will be possible to validate the effect of pool TH and inter-wrapper flow on global natural convection at the same time; for integral validation, PHENIX [24], EBR-II [32] and FFTF [33] tests are or will be available in the short-term.…”
Section: Validation Stepmentioning
confidence: 99%
“…5). Thermal stratification and mixing phenomena were investigated in small scale apparatus like the TALL-3D facility [29] (Thermal-hydraulic Lead-bismuth Loop with 3D flow test section) developed at KTH (Royal Institute of Technology, Stockholm, Sweden). Solidification/remelting in buoyancy driven lead flow was performed in the SESAME-stand experimental facility by CVR (Research Centre Rez, Czech Republic).…”
Section: Pool Thermal Hydraulicsmentioning
confidence: 99%