2014
DOI: 10.3343/alm.2014.34.6.471
|View full text |Cite
|
Sign up to set email alerts
|

The Sysmex XN-2000 Hematology Autoanalyzer Provides a Highly Accurate Platelet Count than the Former Sysmex XE-2100 System Based on Comparison with the CD41/CD61 Immunoplatelet Reference Method of Flow Cytometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
12
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 4 publications
1
12
0
Order By: Relevance
“…Nevertheless, the degree of agreement for the platelet counts is very high as presented in Figure b, but there are some exceptional points which represent great differences between the two analyzers due to the very low count of these cells in the sample. We have not made a detailed comparative study with low platelet counts between the two analyzers, although other studies showed greater accuracy for the XN‐2000 with low platelet counts because of the fluorescence platelet channel, which is relevant in making the appropriate clinical decisions regarding transfusions in patients with thrombocytopenic disorders.…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, the degree of agreement for the platelet counts is very high as presented in Figure b, but there are some exceptional points which represent great differences between the two analyzers due to the very low count of these cells in the sample. We have not made a detailed comparative study with low platelet counts between the two analyzers, although other studies showed greater accuracy for the XN‐2000 with low platelet counts because of the fluorescence platelet channel, which is relevant in making the appropriate clinical decisions regarding transfusions in patients with thrombocytopenic disorders.…”
Section: Discussionmentioning
confidence: 99%
“…Since the protein contents of leukocytes are much higher than those of platelets, the contamination of platelets with leukocytes can affect significantly the quality of the measured platelet proteome. Thus, we checked the purity of our platelet samples and leukocyte contamination during our platelet preparation by flow cytometric analysis with CD45 and CD61 labeling, as previously described (22,23), using the Fig. S1), which corresponded to 2-6 leukocytes per 1×10 4 platelets and also to 1-3% protein contamination based on the estimate previously described (24,25).…”
Section: Methodsmentioning
confidence: 99%
“…Our study also showed that the XN-550 analyzer would yield higher platelet count than the XE-2100 analyzer using PLF-O method, with minimal bias compared to the XN-3000 analyzer using PLT-F method. Given that the XN-series using PLT-F method was reported to provide a highly accurate platelet count (high values) than the former XE-2100 analyzer using PLT-O method based on the comparison with immunoplatelet reference method [11], our result would support the speculation that the XN-550 analyzer can provide more accurate platelet counts than the XE-2100 analyzer, as the XN-3000 analyzer does.…”
mentioning
confidence: 53%