2011
DOI: 10.1016/j.optcom.2010.09.072
|View full text |Cite
|
Sign up to set email alerts
|

The study of wavelength modulation off-axis integrated cavity output spectroscopy in the case of Lorentzian absorption profile

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…56 DFB, distributed feedback; LDC, laser diode controller; OA-ICOS, off-axis integrated cavity output spectroscopy; PZTD, piezoelectric transducer diver sensitivity of the OA-ICOS system by a factor of 5-20. [56][57][58][59][60][61][62] It should be noted that the enhancement of wavelength modulation is not set in stone in OA-ICOS system. 63 Generally when the cavity mirrors with low reflectivity (<0.998) are used, there is a relatively strong optical intensity in the transmitted signal, and the laser amplitude fluctuations dominate the overall noise level, thus a high sensitivity improvement is attainable in this region.…”
Section: Wavelength Modulation Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…56 DFB, distributed feedback; LDC, laser diode controller; OA-ICOS, off-axis integrated cavity output spectroscopy; PZTD, piezoelectric transducer diver sensitivity of the OA-ICOS system by a factor of 5-20. [56][57][58][59][60][61][62] It should be noted that the enhancement of wavelength modulation is not set in stone in OA-ICOS system. 63 Generally when the cavity mirrors with low reflectivity (<0.998) are used, there is a relatively strong optical intensity in the transmitted signal, and the laser amplitude fluctuations dominate the overall noise level, thus a high sensitivity improvement is attainable in this region.…”
Section: Wavelength Modulation Spectroscopymentioning
confidence: 99%
“…Wavelength modulation can effectively reduce 1/ f noise and other low‐frequency noise, as well as eliminate the annoying baseline slope normally encountered in diode laser absorption spectroscopy. The addition of wavelength modulation has been shown to increase the detection sensitivity of the OA‐ICOS system by a factor of 5–20 56–62 …”
Section: Recent Progresses For Improving Performances Of Oa‐icosmentioning
confidence: 99%
“…As shown in Figure 1, In the early days, we used ultra-low expansion coefficient glass-ceramic as the resonant cavity and used the high reflectivity mirrors with a reflectivity of 99.99% as the cavity mirror. Combined with precision optical polishing and optical glue technology, we established a high-stability, low-loss folded-type optical cavity [7][8][9][10] . At the same time, the narrow-spectrum near-infrared DFB laser commonly used in the field of communication is used as the light source.…”
Section: Previous Experimentsmentioning
confidence: 99%
“…Different from CRDS, CEAS measures the intensity of the transmitted light from the cavity by a photodetector, which reduces the response frequency requirement of the system. Many types of CEAS have been proposed, which can be divided into two categories: integrated cavity output spectroscopy (ICOS) [14,15,16] and mode-locking CEAS. In ICOS, the laser frequency is swept through some cavity modes, and the integrated transmission of these cavity modes is measured.…”
Section: Introductionmentioning
confidence: 99%