2019
DOI: 10.12783/dteees/gmee2018/27547
|View full text |Cite
|
Sign up to set email alerts
|

The Study of Burial Depth and Risk Assessment of Submarine Power Cable

Abstract: In this paper, the determination of submarine cable burial depth and risk assessment method are studied. The main objective of the method is to optimize the burial depth of submarine cable in terms of specifying an economically feasible buried depth which ensures a satisfactory level of protection and by acceptable risk. The risk factors influencing the burial depth of submarine cables were analyzed. The primary risk to which submarine cables are exposed is anchoring, while the environmental factor and the cab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 2 publications
0
2
0
Order By: Relevance
“…Calculating the probability and depth of penetration of the anchor deployment near the submarine cable is studied. This method can reduce the cost of protection while providing lines with better protection and guiding the specification of the buried depth of subsea power cables [12]. Combining these to equations gives the following expression for the terminal energy as stated in DNV-RP-F107 is as follows [2][8]: a.…”
Section: Dropped Anchor Energy Analysismentioning
confidence: 99%
“…Calculating the probability and depth of penetration of the anchor deployment near the submarine cable is studied. This method can reduce the cost of protection while providing lines with better protection and guiding the specification of the buried depth of subsea power cables [12]. Combining these to equations gives the following expression for the terminal energy as stated in DNV-RP-F107 is as follows [2][8]: a.…”
Section: Dropped Anchor Energy Analysismentioning
confidence: 99%
“…The main purpose of cable grounding is to ensure safety during cable operation and maintenance. Once the insulation of the metal sheath of the high-voltage cable is damaged, it will inevitably cause multi-point grounding of the metal sheath, which will lead to a significant increase in the sheath circulating current value, thereby accelerating the aging of the cable insulation, shortening the service life and transmission capacity of the cable, and threatening the safe and stable operation of the power system [6][7][8]. Therefore, Therefore, before laying the cable, it is necessary to simulate and calculate the grounding method of the cable to eliminate the above-mentioned safety hazards.…”
Section: Introductionmentioning
confidence: 99%