2008
DOI: 10.1016/j.physc.2008.05.205
|View full text |Cite
|
Sign up to set email alerts
|

The study of a rotating method for fabricating Y1Ba2Cu3O7−x films by TFA-MOD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 9 publications
1
2
0
Order By: Relevance
“…In our study, a vial of PAn was stored for three months and remained clear without any precipitation. Using PAn and the fabrication procedure previously described in the experimental details section, YBCO film with the optimized performance could be obtained when the maximum temperature of pyrolysis (MTP) was 600 • C. Its J c was as high as 3.8 MA cm −2 (77 K, self-field, about 250 nm thick), which is comparable with those of YBCO films reportedly fabricated by the conventional all TFA solution [22] and low-fluorine solution [23]. As shown in figure 1, the pyrolysis duration was approximately 40-60 min, which was much shorter than that of the conventional TFA-MOD method [9].…”
Section: Resultssupporting
confidence: 56%
“…In our study, a vial of PAn was stored for three months and remained clear without any precipitation. Using PAn and the fabrication procedure previously described in the experimental details section, YBCO film with the optimized performance could be obtained when the maximum temperature of pyrolysis (MTP) was 600 • C. Its J c was as high as 3.8 MA cm −2 (77 K, self-field, about 250 nm thick), which is comparable with those of YBCO films reportedly fabricated by the conventional all TFA solution [22] and low-fluorine solution [23]. As shown in figure 1, the pyrolysis duration was approximately 40-60 min, which was much shorter than that of the conventional TFA-MOD method [9].…”
Section: Resultssupporting
confidence: 56%
“…Growth mechanism and influence of various processing parameters for TFA-MOD method have been widely investigated [8][9][10][11][12][13][14]. However, to our knowledge, little attention has been paid to the effect of solvent used for precursor solution preparation.…”
Section: Introductionmentioning
confidence: 99%
“…Methanol is the most commonly used solvent in TFA-MOD route [1][2][3][4][5][6][7][8][9][10][11][12][13][14]. It is toxic and may cause death or blindness [15], which would involve serious health risk for industrial manufacture.…”
Section: Introductionmentioning
confidence: 99%