2018 IEEE Energy Conversion Congress and Exposition (ECCE) 2018
DOI: 10.1109/ecce.2018.8557615
|View full text |Cite
|
Sign up to set email alerts
|

The Steady-State and Fault Ride-Through Control Strategies of Soft Normally Open Point in Distribution Network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…Since each converter can control two state quantities at the same time, the reactive power of the converter can also be controlled [24]- [26]. When a fault occurs, by switching the control mode, the converter can control the voltage and frequency of the non-faulty area of the power system to achieve uninterrupted power supply [27]. In this paper, the research focuses on the small-signal model in normal working mode.…”
Section: Snop Aims To Replace Traditional Normally Open Point (Nop)mentioning
confidence: 99%
See 1 more Smart Citation
“…Since each converter can control two state quantities at the same time, the reactive power of the converter can also be controlled [24]- [26]. When a fault occurs, by switching the control mode, the converter can control the voltage and frequency of the non-faulty area of the power system to achieve uninterrupted power supply [27]. In this paper, the research focuses on the small-signal model in normal working mode.…”
Section: Snop Aims To Replace Traditional Normally Open Point (Nop)mentioning
confidence: 99%
“…According to the generalized instantaneous reactive power theory [35], P k and Q k can be calculated as (26) Let ( 27) Linearizing ( 25) and combining with (27), it can be derived that (28) where (29) The current controller of the inner loop can be expressed as (30) Let ( 31) Linearizing (30) and combining with (31), it can be derived that (32) Due to a certain delay between the output of the inverter and the output of control system, the modulation process of the converter can be regarded as a first-order inertia link, i.e.…”
Section: Small-signal Model Of the Control System Of Pq Terminalmentioning
confidence: 99%
“…FRT application by SOP based on a B2B half-bridge MMC is proposed in [64]. The simulation result is given for unbalance current compensation using negative sequence current compensation method during unbalanced faults.…”
Section: ) Fault Ride Throughmentioning
confidence: 99%
“…On this basis, FMSS plays a significant role in facilitating the feeder load balance, reducing network losses, improving voltage quality and eliminating the fluctuation of intermittent energy. When the system fails, FMSS can achieve uninterrupted power supply for important users and reduce the power outage range and the power outage time through multi‐terminal coordinated scheduling, thereby enhancing system reliability [5, 6]. However, FMSS access has changed the closed‐loop design and open‐loop operation power supply mode in distribution network.…”
Section: Introductionmentioning
confidence: 99%