The SPECIES beamline at the MAX IV Laboratory: a facility for soft X-ray RIXS and APXPS

Abstract: SPECIES is an undulator-based soft X-ray beamline that replaced the old I511 beamline at the MAX II storage ring. SPECIES is aimed at high-resolution ambient-pressure X-ray photoelectron spectroscopy (APXPS), near-edge X-ray absorption fine-structure (NEXAFS), X-ray emission spectroscopy (XES) and resonant inelastic X-ray scattering (RIXS) experiments. The beamline has two branches that use a common elliptically polarizing undulator and monochromator. The beam is switched between the two branches by changing t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
36
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 44 publications
(36 citation statements)
references
References 33 publications
(37 reference statements)
0
36
0
Order By: Relevance
“…Although the total power of an undulator with a high K value is in general higher than that of an undulator with a low K value, the power densities of equally long devices do not scale similarly. As an example, we can compare the present undulator, with K = 10.065 at 4.3 eV, to the undulator of the SPECIES beamline[9] at the MAX IV Laboratory. That undulator was designed for an equally long straight section and to have K max = 4.88 at 27 eV.…”
mentioning
confidence: 99%
“…Although the total power of an undulator with a high K value is in general higher than that of an undulator with a low K value, the power densities of equally long devices do not scale similarly. As an example, we can compare the present undulator, with K = 10.065 at 4.3 eV, to the undulator of the SPECIES beamline[9] at the MAX IV Laboratory. That undulator was designed for an equally long straight section and to have K max = 4.88 at 27 eV.…”
mentioning
confidence: 99%
“…The experiments were carried out at the APXPS end station [17,18] of the SPECIES beamline [19] at the MAX IV Laboratory in Lund, Sweden. In short, the end station is equipped with a hemispherical SPECS Phoibos NAP-150 electron energy analyzer and allows for measurements both at ultra-high vacuum (UHV) conditions as well as up to 25 mbar in an ambient pressure (AP) cell.…”
Section: Methodsmentioning
confidence: 99%
“…APXPS measurements were performed at the APXPS branch line of the SPECIES beamline 15,16 at the MAX IV Laboratory. As the beamline currently is in commissioning, the equipped unmonochromatized SPECS XR-50 17 X-ray anode was used to generate Mg K radiation (1253.64 eV) for spectrum acquisition.…”
Section: Ambient Pressure Xpsmentioning
confidence: 99%