2010
DOI: 10.1016/j.marchem.2010.02.003
|View full text |Cite
|
Sign up to set email alerts
|

The significance of atmospheric inputs of soluble and particulate major and trace metals to the eastern Mediterranean seawater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
40
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
8
2

Relationship

5
5

Authors

Journals

citations
Cited by 66 publications
(44 citation statements)
references
References 43 publications
(60 reference statements)
4
40
0
Order By: Relevance
“…After cooling to room temperature, the digested solution was transferred to an acid-cleaned polyethylene container and stored in the freezer. The solutions thus obtained were finally analyzed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS, Thermo Electron X Series), following the technique described in detail by Theodosi et al (2010c). Recoveries obtained for certified reference materials (MESS-3, GBW 07313 and BCSS-1) were excellent, ranging from 90.0-104.1 % for all studied elements except Al (60 %) which was corrected accordingly.…”
Section: Discussionmentioning
confidence: 99%
“…After cooling to room temperature, the digested solution was transferred to an acid-cleaned polyethylene container and stored in the freezer. The solutions thus obtained were finally analyzed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS, Thermo Electron X Series), following the technique described in detail by Theodosi et al (2010c). Recoveries obtained for certified reference materials (MESS-3, GBW 07313 and BCSS-1) were excellent, ranging from 90.0-104.1 % for all studied elements except Al (60 %) which was corrected accordingly.…”
Section: Discussionmentioning
confidence: 99%
“…Trace elements and metals were determined using an inductively coupled plasma mass spectrometry (Thermo Electron X Series) after the acid microwave digestion of samples (a filter disc of 1.8 cm in diameter) as reported by Theodosi et al (2010b …”
Section: Determination Of Trace Elements Metals and Water-soluble Irmentioning
confidence: 99%
“…More details on the IC method are given by Bardouki et al (2003). An acid microwave digestion procedure followed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS, Thermo Electron X Series) was applied to measure PM elemental concentrations (V, Cr, Mn, Fe, Ni, Cu, Cd and Pb) (Theodosi et al, 2010b).…”
Section: Sampling and Analytical Techniquesmentioning
confidence: 99%