The SEVAN Worldwide network of particle detectors: 10 years of operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 28 publications
(9 citation statements)
references
References 42 publications
0
8
0
Order By: Relevance
“…Estimates of this quantity vary widely. In the nuclear physics literature on TGEs, the free passage distance is often associated with the cloud base height Chilingarian, 2018aChilingarian, , 2018bChilingarian, Hovsepyan, Svechnikova, & Zazyan, 2021) which for the Aragats station (3.2 km MSL) is often 100m or less.…”
Section: Surface Detectability Of Energetic Electrons In Tgesmentioning
confidence: 99%
“…Estimates of this quantity vary widely. In the nuclear physics literature on TGEs, the free passage distance is often associated with the cloud base height Chilingarian, 2018aChilingarian, , 2018bChilingarian, Hovsepyan, Svechnikova, & Zazyan, 2021) which for the Aragats station (3.2 km MSL) is often 100m or less.…”
Section: Surface Detectability Of Energetic Electrons In Tgesmentioning
confidence: 99%
“…Muons do not multiply in the electric field as electrons; however, electric fields lead to the modernization of their energy spectra and induce a very interesting muon stopping effect, used for the estimation of the maximum energy of the atmospheric electric field [16]. For the estimation of the maximum field, we use the observation of the ever-largest TGE measured at Lomnicky Stit in Slovakia ( [17] by SEVAN European particle detector network [18]).…”
Section: Discussionmentioning
confidence: 99%
“…Cutoff rigidity of the NM at LS is 3.84 GV. The second is the SEVAN system, which has three separated plastic scintillators as detectors (Chilingarian et al, 2018). The upper and lower scintillators have the dimensions 100 × 100 × 5 cm and are separated from the middle scintillator by 4.5-cm-thick and 100 × 100 cm-wide lead absorbers.…”
Section: Measurement Setupmentioning
confidence: 99%
“…The middle detector is composed of five plastic slabs and has the dimensions 50 × 50 × 25 cm. The upper detector-channel 1-is mainly sensitive to low-energy charged particles, mainly electrons, and partly also to gamma rays (Chilingarian et al, 2018). The estimated energy threshold, considering the roof above the detector, is 7-8 MeV (Kudela et al, 2017).…”
Section: Measurement Setupmentioning
confidence: 99%