1993
DOI: 10.1177/089686089301300310
|View full text |Cite
|
Sign up to set email alerts
|

The Serum Complement System in Children on Continuous Ambulatory Peritoneal Dialysis

Abstract: Objective During continuous ambulatory peritoneal dialysis (CAPD), the loss of complement factors via the dialysate may cause complement deficiencies. This hypothesis was tested in a group of children treated with CAPD. Design Classical (CH50) and alternative (AP50) complement activity and serum levels of factors C1 q, C3, C4, C3d, B, D, and P in CAPD patients were compared to normal controls and to children with preterminal renal failure. Setting Patients were seen in a university hospital; normal controls we… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
1
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 27 publications
0
11
1
1
Order By: Relevance
“…However, MBL has so far not been assessed in peritoneal dialysates. Furthermore, serum levels of C1q, C4, C3d, factor D, and properdin were shown to be higher in pediatric PD patients compared to healthy controls, however, not in comparison to patients with ESKD ( 87 ). Overall, the higher plasma levels of the complement components are likely caused by increased synthesis by the liver due to the pro-inflammatory state in ESKD patients.…”
Section: Peritoneal Dialysismentioning
confidence: 89%
“…However, MBL has so far not been assessed in peritoneal dialysates. Furthermore, serum levels of C1q, C4, C3d, factor D, and properdin were shown to be higher in pediatric PD patients compared to healthy controls, however, not in comparison to patients with ESKD ( 87 ). Overall, the higher plasma levels of the complement components are likely caused by increased synthesis by the liver due to the pro-inflammatory state in ESKD patients.…”
Section: Peritoneal Dialysismentioning
confidence: 89%
“…Complement component 3 was assessed by radial immunodiffusion using monospecific polyclonal rabbit antisera, and C3d was measured by rocket electrophoresis. 41 , 42 All measurements were performed in a single assay. Triglycerides and C-reactive protein (CRP) levels were measured with the Abbott Architect C16000 system (Abbott Diagnostics, Chicago, IL).…”
Section: Methodsmentioning
confidence: 99%
“…Serum was prepared by coagulation at room temperature and after centrifugation the samples were stored at −80°C within one hour after collection. C3 and C3d were measured in serum samples as described [39] , [40] . All C3 and C3d measurements in this study were performed in a single experiment, except for the final sample in months 14–22.…”
Section: Methodsmentioning
confidence: 99%