1998
DOI: 10.1080/1047322x.1998.10389161
|View full text |Cite
|
Sign up to set email alerts
|

The Selected Ion Flow Tube Method for Workplace Analyses of Trace Gases in Air and Breath: Its Scope, Validation, and Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0
1

Year Published

1999
1999
2022
2022

Publication Types

Select...
7
2

Relationship

7
2

Authors

Journals

citations
Cited by 43 publications
(37 citation statements)
references
References 20 publications
0
36
0
1
Order By: Relevance
“…The real-time variations in several of these VOCs can be obtained by operating the SIFT-MS instrument in the MIM mode (see Section III). Clearly, there is obvious value in the real-time rapid analyses of industrial (factory) air as part of good health and safety practice (Š paněl et al, 1996;Smith et al, 1998).…”
Section: Laboratory Airmentioning
confidence: 99%
“…The real-time variations in several of these VOCs can be obtained by operating the SIFT-MS instrument in the MIM mode (see Section III). Clearly, there is obvious value in the real-time rapid analyses of industrial (factory) air as part of good health and safety practice (Š paněl et al, 1996;Smith et al, 1998).…”
Section: Laboratory Airmentioning
confidence: 99%
“…This is now a routine aspect of all SIFT-MS analyses of breath. So, although validation studies have been carried out (Š paněl et al, 1997;Smith et al, 1998), calibration of SIFT-MS instrument for each individual compounds using prepared mixtures, which is difficult at low (ppb) concentrations, is not required when breath humidity can be measured.…”
Section: Progress In Sift-msmentioning
confidence: 99%
“…During the development of SIFT-MS we have consciously carried out pilot studies in several areas to demonstrate its potential, including exposure to toxic gases in health and safety studies (Smith et al, 1998), cell biology (Smith, Wang, & Š paněl, 2002a;, the analysis of environmental air in pollution studies, in particular the emissions from petrol and diesel combustion engines (Smith, Cheng, & Š paněl, 2002;Smith et al, 2004), the odorous emissions from animal waste (Smith, Š paněl, & Jones, 2000) and the rumen of diary cows (Dewhurst et al, 2001), and in food flavor research (Š paněl & Smith, 1999d). We have summarized these pilot studies and discussed other areas in which SIFT-MS can be valuable in our previous review .…”
Section: Other Miscellaneous Applications Of Sift-msmentioning
confidence: 99%
“…We have developed selected ion flow tube mass spectrometry, SIFT-MS, for trace gas analysis of air with special attention given to exhaled (very humid) breath [11,12]. Using SIFT-MS we can readily measure the concentrations of the major breath metabolites, including acetone, in single exhalations on-line and in real time [11][12][13][14][15]. It is also straightforward to quantify trace gases in urine headspace using SIFT-MS [8,16].…”
Section: Introductionmentioning
confidence: 99%