The science case of the FRS Ion Catcher for FAIR Phase-0

Abstract: The FRS Ion Catcher at GSI enables precision experiments with thermalized projectile and fission fragments. At the same time it serves as a test facility for the Low-Energy Branch of the Super-FRS at FAIR. The FRS Ion Catcher has been commissioned and its performance has been characterized in five experiments with 238 U and 124 Xe projectile and fission fragments produced at energies in the range from 300 to 1000 MeV/u. High and almost element-independent efficiencies for the thermalization of short-lived nucl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 29 publications
(30 reference statements)
0
8
0
Order By: Relevance
“…Several experimental runs will be performed during FAIR phase 0 at GSI/FAIR. These experiments include mass measurements at N = 126 below 208 Pb [93] and for N = Z nuclides below 100 Sn [94]. Moreover the system will be used to identify reactions and decay products and thereby measure β-delayed neutron emission probabilities [95] and multinucleon transfer reaction product cross sections [96].…”
Section: Discussionmentioning
confidence: 99%
“…Several experimental runs will be performed during FAIR phase 0 at GSI/FAIR. These experiments include mass measurements at N = 126 below 208 Pb [93] and for N = Z nuclides below 100 Sn [94]. Moreover the system will be used to identify reactions and decay products and thereby measure β-delayed neutron emission probabilities [95] and multinucleon transfer reaction product cross sections [96].…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, the unique features in our implementation are broadband and high-resolving-power measurements in a non-scanning manner [21], fast extraction at the FRS-IC [15],fast mass measurement at the MR-TOF-MS [21], and extraordinary cleanliness of the CSC [25]. The latter feature is the source for the essential element independence of the CSC, including comparison of a noble element (Rn), and a most reactive one (Th) [26].…”
Section: Description Of the Methodsmentioning
confidence: 99%
“…The FRS Ion Catcher (FRS-IC) [19,20] is a test facility for the Low-Energy Branch of the Super-FRS [21,22] at FAIR. It is installed at the end of the symmetric branch of the fragment separator FRS [23] at GSI and consists of three major parts: a gas-filled cryogenic stopping cell (CSC) [6,24,25], an RFQ beamline [24] and a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) [26,27].…”
Section: Methodsmentioning
confidence: 99%