The role of impurities in thermally stimulated luminescence of MgO:Mn2+ and MgO:V2+ crystals irradiated in a reactor

Abstract: The high‐temperature thermally stimulated luminescence (TSL) of nominally pure MgO crystals and MgO crystals with excessive amounts of paramagnetic manganese and vanadium ions irradiated in a reactor has been studied. It was observed that the influence of impurity on the TSL of crystal is different at low and relatively high doses. (© 2007 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…The linear response was confirmed the tested range and calculated coefficient of determinations of 0.001, 0.01 and 0.1 % Crdoped MgO are 0.9759, 0.9815 and 0.9649, respectively. It is an equivalent sensitivity with commercial personal dosimeters and the highest sensitivity for MgO among the earlier reported works we could find [46][47][48]. Dosimeter having a linear response is advantageous because it enables us to easily and accurately calibrate the dose.…”
Section: Dosimeter Propertiesmentioning
confidence: 97%
“…The linear response was confirmed the tested range and calculated coefficient of determinations of 0.001, 0.01 and 0.1 % Crdoped MgO are 0.9759, 0.9815 and 0.9649, respectively. It is an equivalent sensitivity with commercial personal dosimeters and the highest sensitivity for MgO among the earlier reported works we could find [46][47][48]. Dosimeter having a linear response is advantageous because it enables us to easily and accurately calibrate the dose.…”
Section: Dosimeter Propertiesmentioning
confidence: 97%
“…It is an equivalent sensitivity with commercial personal dosimeters and the highest sensitivity for MgO among the earlier reported works we could find (Boss et al, 2006;Kvatchadze et al, 2007;Soliman, 2009).…”
Section: Dosimeter Propertiesmentioning
confidence: 50%
“…All measurements were made at the room temperature. TSL curves were registered by a high-temperature (300-775 K) computerized device in the regime of photon counting with the permanent velocity of sample heating 1 K/s [3].…”
Section: Samples and Methodsmentioning
confidence: 99%
“…The spectral analysis of the TSL peak at 450 K carried out by interference filters showed its complex nature [3]. This is caused, at least, by two factors: by structural defects of vacancy type (emission at 405 nm and 514 nm that refers to F + -and F-centers, respectively) and by impurity ions (emission at 457 nm, 617 nm, and 660 nm caused by the ions of transition metals 2+…”
Section: Samples and Methodsmentioning