2021
DOI: 10.1016/j.chroma.2021.461963
|View full text |Cite
|
Sign up to set email alerts
|

The retention index approach in liquid chromatography: An historical review and recent advances

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
23
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(23 citation statements)
references
References 59 publications
0
23
0
Order By: Relevance
“…The LRI system is routinely used in gas chromatography since it has been introduced for the first time [ 56 ]; it was abandoned after a few attempts in LC due to a poor repeatability at inter-laboratory levels [ 57 ]. Recently, it was re-proposed in our laboratory for the identification of lipids [ 58 ] and OHC compounds [ 51 , 52 , 59 ] through LC methods combined with different detection systems, being confident about the highest batch-to-batch reproducibility of LC columns and instrumentations achieved in the last years.…”
Section: Introductionmentioning
confidence: 99%
“…The LRI system is routinely used in gas chromatography since it has been introduced for the first time [ 56 ]; it was abandoned after a few attempts in LC due to a poor repeatability at inter-laboratory levels [ 57 ]. Recently, it was re-proposed in our laboratory for the identification of lipids [ 58 ] and OHC compounds [ 51 , 52 , 59 ] through LC methods combined with different detection systems, being confident about the highest batch-to-batch reproducibility of LC columns and instrumentations achieved in the last years.…”
Section: Introductionmentioning
confidence: 99%
“…It is noteworthy that the Δ value between the experimental and tabulated LRI values (LRI exp and LRI tab , respectively) for almost all the compounds remained inside the tolerance window of ± 15 units, as derived from previous calculation about the separation number of the applied chromatographic method [ 19 , 21 ]. Out of a total of 62 identified compounds, 31 TAGs were positively matched with the LRI database (ΔLRI ≤ 15), and an additional 4 TAGs differed from the tabulated values of 17–20 units, mainly due to coelutions or very low peak intensity.…”
Section: Resultsmentioning
confidence: 59%
“…Particularly, each odd carbon chain number reference compound is eluted few seconds earlier or later than the subsequent or previous even carbon chain number TAG. Moreover, it can be highlighted that even PN regions, as well as the reference TAGs are quite equidistant from each other under the linear gradient used for the LC separation, thus, guaranteeing the proper functioning of the LRI strategy [ 21 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations