2019
DOI: 10.1088/1757-899x/698/2/022089
|View full text |Cite
|
Sign up to set email alerts
|

The research on bearing capacity of supports with annular section

Abstract: Our research work on the physical and mechanical properties of centrifuged concrete, the strength and deformability of cylindrical and conical transmission towers made it possible to reveal some incorrect calculations according to the old and new standards. To identify discrepancies in the calculations for the supports with annular section according to the SNiP 2.03.01-84 and according to the SP 63.13330.2012, we carried out the numerical experiments on the example of the transmission tower supports. As the te… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…In this work, which is a continuation of the previous studies [8][9][10], the results of a numerical experiment on the study of the bearing capacity, bending rigidity and the critical force of annular struts under short-term and long-term loads are presented. A cylindrical support was adopted as a test sample PTL according to GOST 22687.2, the parameters of which are given in Table 1.…”
Section: Main Partmentioning
confidence: 88%
See 2 more Smart Citations
“…In this work, which is a continuation of the previous studies [8][9][10], the results of a numerical experiment on the study of the bearing capacity, bending rigidity and the critical force of annular struts under short-term and long-term loads are presented. A cylindrical support was adopted as a test sample PTL according to GOST 22687.2, the parameters of which are given in Table 1.…”
Section: Main Partmentioning
confidence: 88%
“…The methodology for calculating such structures in the new standards BC 63.13330.2018 [7] has not undergone significant changes. However, we analyzed in detail some features of the calculation according to the new standards in [8].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Вышеуказанные исследования легли в основу норм СНиП 2.03.01-84 «Бетонные и железобетонные конструкции» для расчета конструкций кольцевого сечения из железобетонов. Что касается новых норм СП 63.13330.2018 «Бетонные и железобетонные конструкции», то ранее предложенный метод расчета конструкций в них в существенной степени не изменился, хотя и появились некоторые особенности расчета, что подробно описано в [7].…”
unclassified
“…построены в виде графиков пропорциональные зависимости, наглядно показывающие изменения критической силы цилиндрических стоек при длительных нагружениях с учетом изменения влажности окружающей среды и связанного с этим изменения модуля деформации конструкций.− подробно изучено изменение несущей способности исследуемых элементов с увеличением отношения продольной силы к критической продольной силе.Материалы и методы. В данной статье, являющейся продолжением ранее выполненных изысканий[7][8][9], приведены результаты численного эксперимента по изучению несущей способности, жесткости на изгиб, максимальной силы для опор линий электропередач при кратковременном и длительном действии нагрузок. Как исследуемый образец взята цилиндрическая опора линии электропередач по ГОСТ 22687.2.𝑀 𝑢𝑙𝑡 ≤ (𝑅 𝑏 𝐴 𝑏 𝑟 𝑚 + 𝑅 𝑠𝑐 𝐴 𝑠,𝑡𝑜𝑡 𝑟 𝑠 )…”
unclassified