2017
DOI: 10.3906/sag-1702-44
|View full text |Cite
|
Sign up to set email alerts
|

The relationship between the degree of skin fibrosis by sonoelastography and the degree of pulmonary involvement in scleroderma

Abstract: Background/aim: This study aimed to assess the relationship between skin fibrosis as determined by sonoelastography and the degree of pulmonary involvement as determined by high-resolution computed tomography (HRCT) in patients with diffuse cutaneous systemic sclerosis (dcSSc). Materials and methods:This prospective study included 40 patients with dcSSc. All patients with HRCT scans underwent conventional ultrasonography and sonoelastography to determine skin thickness and degree of fibrosis. The degree of fib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…81 Several studies have assessed skin stiffness using shearwave elastography [83][84][85][86] or qualitative colour-scale US elastography. 87 Overall, these studies found significantly higher shear-wave velocity values in SSc patients than in controls, at almost all of the Rodnan skin sites. [83][84][85][86] In addition, Yang et al 83 reported that the skin stiffness as assessed by skin wave elastography was more sensitive to detect subtle skin changes than B-mode US.…”
Section: Skin Us and Elastography In Sscmentioning
confidence: 87%
“…81 Several studies have assessed skin stiffness using shearwave elastography [83][84][85][86] or qualitative colour-scale US elastography. 87 Overall, these studies found significantly higher shear-wave velocity values in SSc patients than in controls, at almost all of the Rodnan skin sites. [83][84][85][86] In addition, Yang et al 83 reported that the skin stiffness as assessed by skin wave elastography was more sensitive to detect subtle skin changes than B-mode US.…”
Section: Skin Us and Elastography In Sscmentioning
confidence: 87%
“…There is only one study in the literature that compare skin stiffness detected by US elastography with lung involvement. In this study, semiquantitative strain US elastography method were used 16 . Skin stiffness was classified according to the color scale, but patients with low firmness were not included in this study.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, semiquantitative strain US elastography method were used. 16 Skin stiffness was classified according to the color scale, but patients with low firmness were not included in this study. It has been reported that there is a relationship between moderate and high skin stiffness and lung involvement.…”
Section: Discussionmentioning
confidence: 99%
“…Elastography was described in a quantitative or in a semi-quantitative color scale 35,68,[71][72][73] (table S3). Quantitative values were reported in different units across studies, i.e., meters per second, m/s; elastic modulus in Kilopascal, kPa; or global percentage of hardness.…”
Section: Description Of Image Acquisition and Analysismentioning
confidence: 99%