2012
DOI: 10.1016/j.diagmicrobio.2012.01.009
|View full text |Cite
|
Sign up to set email alerts
|

The preanalytical optimization of blood cultures: a review and the clinical importance of benchmarking in 5 Belgian hospitals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
44
0
3

Year Published

2013
2013
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(51 citation statements)
references
References 59 publications
4
44
0
3
Order By: Relevance
“…found that only 45% of patients had adequate numbers of BC sets and only 13% had optimal sample volumes (that is ≥10 ml per bottle) [28]. The authors of a review on true-positive rate, contamination rate, and collected blood volume of BC bottles in five Belgian hospital laboratories found that more than one-third of the BC bottles handled were incorrectly filled, irrespective of the manufacturer of the blood culture vials [29]. …”
Section: Discussionmentioning
confidence: 99%
“…found that only 45% of patients had adequate numbers of BC sets and only 13% had optimal sample volumes (that is ≥10 ml per bottle) [28]. The authors of a review on true-positive rate, contamination rate, and collected blood volume of BC bottles in five Belgian hospital laboratories found that more than one-third of the BC bottles handled were incorrectly filled, irrespective of the manufacturer of the blood culture vials [29]. …”
Section: Discussionmentioning
confidence: 99%
“…BCs may be performed selectively in patients with pneumonia or skin-soft tissue infections. 51 The review also provides a listing of indications for follow-up BCs.…”
Section: Clinical Indications For Bcsmentioning
confidence: 99%
“…Commercial bottles contain substantially more vacuum than is needed to adequately fill the bottles, ensuring rapid filling. 51,123 Obtaining blood for culture with a bottle in a horizontal position allows for only an estimate of the proper quantity. Although the bottle has a printed volume scale, it only helps if the bottle is maintained in a vertical position during filling.…”
Section: Volumementioning
confidence: 99%
“…The weight difference in grams was divided by the density of blood (1.060 g/ml [4]) to measure the volume of blood in the bottle. We used a volume of 8 ml (i.e., 2 ml below the recommended volume) as the minimal norm, as previously proposed (5). All data were stored and analyzed using SPSS version 18.0 (IBM).…”
mentioning
confidence: 99%