1991
DOI: 10.1016/0883-2889(91)90003-j
|View full text |Cite
|
Sign up to set email alerts
|

The potential of perturbed angular correlation of gamma rays as a tool for dynamic studies of peptides/proteins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

1995
1995
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 23 publications
0
9
0
Order By: Relevance
“…All water was distilled twice, and adjustment of pH was done by using either NaOH or sulfuric acid in order to avoid Cl™. All glassware was washed in aqua regia, and all water was passed through a diethylenetriaminepentaacetate-coupled gel (height = 3 cm, diameter = 1 cm) (Bauer et al, 1991b) in order to lower the contamination of metals to less than 0.1 µ .…”
Section: Methodsmentioning
confidence: 99%
“…All water was distilled twice, and adjustment of pH was done by using either NaOH or sulfuric acid in order to avoid Cl™. All glassware was washed in aqua regia, and all water was passed through a diethylenetriaminepentaacetate-coupled gel (height = 3 cm, diameter = 1 cm) (Bauer et al, 1991b) in order to lower the contamination of metals to less than 0.1 µ .…”
Section: Methodsmentioning
confidence: 99%
“…The spectral parameters for all the complexes of LADH with coenzyme and/or inhibitors investigated by PAC (Andersson et al, 1982;Bauer et al, 1991 a;Hemmingsen et al, 1995; this work) fall into one of two groups: a low o,, region (120-230 Mrad/s) or a high o, region (270-350 Mrad/s); 9 is relatively constant in all experiments. From the results in this work it has become clear that there is a connection between the presence of a charged solvent ligand and spectral parameters in the low w, region.…”
Section: Fractionmentioning
confidence: 99%
“…This is mainly due to the low concentrations of the radiometals and chelators. However, the common methods of determination are thin layer chromatography and high-performance liquid chromatography, in addition to further animal studies. , PAC is a useful technique for these purposes, as is presented in a number of works. However, it has not become a routine technique, mainly due to uncertainty concerning after-effects, the need for a convenient parameter, and a relatively small choice of the radionuclides suitable for PAC. The aim of the present work is to provide an example of the application of PAC and its suitability for the study of a chelator–radionuclide system.…”
Section: Introductionmentioning
confidence: 99%
“…The γ–γ perturbed angular correlation technique is based on the angular correlation between two γ-rays, which is perturbed by the hyperfine interaction of the nuclear electric quadrupole moment ( Q ) with the electric field gradient (EFG) or the nuclear magnetic moment with an extranuclear magnetic field. PAC gives information serving as a “fingerprint” of the local structure. As the PAC can be used to measure changes in the local environment of the nucleus, this technique can be useful for more detailed investigation of the radionuclides attached to a ligand …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation