2007
DOI: 10.1016/j.jhazmat.2006.09.024
|View full text |Cite
|
Sign up to set email alerts
|

The performance of BAF using natural zeolite as filter media under conditions of low temperature and ammonium shock load

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
38
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 77 publications
(45 citation statements)
references
References 13 publications
(13 reference statements)
5
38
0
Order By: Relevance
“…The aeration device introduced the air in an upward direction in order to keep dissolved oxygen (DO) concentrations above 2 mg O 2 L -1 in section TM-P3 (i.e., the reactor was partially aerated). This is one of the innovations of this work, since most of the previous studies with BAF (Villaverde et al 2000;Stephenson et al 2003;Lei et al 2009;Ha et al 2010b;He et al 2007) used fully aerated filters with the aeration device located at the bottom of the reactors. A backwashing system was included in order to remove the excess of both filtered material and biomass (sludge) produced during the biofilter operation.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The aeration device introduced the air in an upward direction in order to keep dissolved oxygen (DO) concentrations above 2 mg O 2 L -1 in section TM-P3 (i.e., the reactor was partially aerated). This is one of the innovations of this work, since most of the previous studies with BAF (Villaverde et al 2000;Stephenson et al 2003;Lei et al 2009;Ha et al 2010b;He et al 2007) used fully aerated filters with the aeration device located at the bottom of the reactors. A backwashing system was included in order to remove the excess of both filtered material and biomass (sludge) produced during the biofilter operation.…”
Section: Methodsmentioning
confidence: 99%
“…Recent studies showed good performance for ammonia removal at HLR up to 3 m h -1 and air-flow rates from 18 to 200 L h -1 (Taghizadeh et al 2007;Schulz and Menningmann 2008;Lei et al 2009;Ha et al 2010b;He et al 2007;Rajakumar et al 2011) in fully aerated biofilters fed with higher ammonia concentrations ([100 mg NH 4 -N L -1 ). The HRT was approximately 50 min, which is in the range (20 min to 2 h) reported by Mendoza-Espinosa and Stephenson (1999) and Ha et al (2010b) for downflow aerated biofilters treating real and synthetic wastewater.…”
Section: Operating Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Until now, a few studies have showed the removal effi ciency of antibiotics by BAF system. Based on the former literature the potential removal mechanisms of organics in BAF could be attributed to microbial degradation and physical adsorption, whereas the synergy of the two effects could also prolong the operation cycle of biological fi lter bed (He et al 2007, Mann et al 1999). However, the removal rates of antibiotics by BAF can vary among different WWTPs and many factors, such as hydraulic loading, HRT and SRT, could affect the removal of target compounds.…”
Section: Removal Of Antibiotics In Baf Systemmentioning
confidence: 99%
“…Biofilters with different media sizes have been applied for different purposes [8]. For example, the filter with media sizes above 6 mm is commonly used in pretreatment, 3-6 mm used in the secondary treatment process, and around 3 mm used in tertiary biofilters [9][10][11][12][13][14]. Empty bed retention time (EBRT) is also a key factor affecting the performance of denitrifying biofilters.…”
Section: Introductionmentioning
confidence: 99%