2013
DOI: 10.1364/oe.21.008652
|View full text |Cite
|
Sign up to set email alerts
|

The performance of 2D array detectors for light sheet based fluorescence correlation spectroscopy

Abstract: Abstract:Single plane illumination microscopy based fluorescence correlation spectroscopy (SPIM-FCS) is a new method for imaging FCS in 3D samples, providing diffusion coefficients, transport, flow velocities and concentrations in an imaging mode. SPIM-FCS records correlation functions over a whole plane in a sample, which requires array detectors for recording the fluorescence signal. Several types of image sensors are suitable for FCS. They differ in properties such as effective area per pixel, quantum effic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
73
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 67 publications
(74 citation statements)
references
References 67 publications
(52 reference statements)
1
73
0
Order By: Relevance
“…This SPAD array was successfully used in wide-field fluorescence-lifetime imaging (FLIM) [12] experiments in the blue/green wavelength range [109]. A 32×32 SPAD array [107] was used in combination with a custom selective plane illumination microscope (SPIM) [111] for performing FCS measurements [112][113]. However, no true single-molecule experiments have been reported so far with these advanced SPAD array detectors, likely due in part to their limited sensitivity.…”
Section: Available Spad Technologiesmentioning
confidence: 99%
“…This SPAD array was successfully used in wide-field fluorescence-lifetime imaging (FLIM) [12] experiments in the blue/green wavelength range [109]. A 32×32 SPAD array [107] was used in combination with a custom selective plane illumination microscope (SPIM) [111] for performing FCS measurements [112][113]. However, no true single-molecule experiments have been reported so far with these advanced SPAD array detectors, likely due in part to their limited sensitivity.…”
Section: Available Spad Technologiesmentioning
confidence: 99%
“…With a large number of pixels, each of them capable of detecting single photons and measuring their arrival time, it is possible to explore phenomena which would be otherwise difficult to study. Among the different approaches that can take advantage of this capability, time-correlated single-photon counting (TCSPC) techniques, which is used for fluorescence lifetime imaging microscopy (FLIM), figure prominently and have been demonstrated using SPAD-based imaging systems [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…As for SPT applications, the orthogonal illumination used in LSs produces ideal imaging conditions, in terms of signal contrast and SNR, required for measuring the mobility and reaction parameters of molecules inside living cells by FCS measurements in 3D samples [191,192]. Interaction between proteins can also be studied by extending the FCS methodology to fluorescence cross-correlation spectroscopy using two colors acquired simultaneously [193].…”
Section: 2c Wavefront Codingmentioning
confidence: 99%