Advances in Fission-Track Geochronology 1998
DOI: 10.1007/978-94-015-9133-1_3
|View full text |Cite
|
Sign up to set email alerts
|

The Parameters That Govern the Accuracy of Fission-Track Age Determinations: A Re-Appraisal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0
2

Year Published

2001
2001
2018
2018

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 21 publications
1
8
0
2
Order By: Relevance
“…Thus, even ages determined with lower closure temperature methods (as the case of the fission-track thermochrology or (U-Th)/He) must give the same results of the methods that have higher closure temperature. Our values for Durango apatite also agree with those obtained by Van den haute et al [13] and Jonckheere [7] with the fission-track /-method (Au and Co monitors).…”
Section: Age Determinationsupporting
confidence: 91%
See 2 more Smart Citations
“…Thus, even ages determined with lower closure temperature methods (as the case of the fission-track thermochrology or (U-Th)/He) must give the same results of the methods that have higher closure temperature. Our values for Durango apatite also agree with those obtained by Van den haute et al [13] and Jonckheere [7] with the fission-track /-method (Au and Co monitors).…”
Section: Age Determinationsupporting
confidence: 91%
“…Ages of Durango samples obtained using the /-method (Au and Co dosimeters) in a well-thermalized nuclear reactor [7,8,13] are in agreement with the ones obtained through U-doped glass monitors (calibrated against uranium thin films). These fission-track ages are also in agreement when determined using the not-so-well thermalized neutron flux (Cd ratio for Au around 6) of the IPEN-CNEN nuclear reactor of São Paulo.…”
Section: Resultsmentioning
confidence: 97%
See 1 more Smart Citation
“…Earlier studies (Bellemans, 1996;Bigazzi et al, 1990;Curvo et al, 2013;De Corte et al, 1991, 1995Jonckheere, 1995;Van den haute et al, 1988Van den haute et al, , 1998 give reason for trusting that the calculated neutron fluences are accurate. The agreement of the uranium concentrations calculated with Eq.…”
Section: Apparent Fission-track Agementioning
confidence: 99%
“…Our contribution sets out from the premise that neutron-fluence measurements using the recommended metal monitors (Au, Co) and wellthermalized irradiation facilities are no longer an issue (Bigazzi et al, 1990;Curvo et al, 2013;De Corte et al, 1991, 1995Van den haute et al, 1988Van den haute et al, , 1998. Our second assumption is that the matter of the fission constant has been settled following recent redeterminations (Eikenberg et al, 1993;Guedes et al, 2000Guedes et al, , 2003Suzuki, 2005;Yoshioka et al, 2005) and reassessments (Holden, 1989;Holden and Hoffman, 2000).…”
Section: Introduction: Premisesmentioning
confidence: 99%