2018 IEEE 59th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON) 2018
DOI: 10.1109/rtucon.2018.8659864
|View full text |Cite
|
Sign up to set email alerts
|

The non-invasive optical glucometer prototype with ellipsoidal reflectors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…Based on the mechanism of image processing at ellipsoidal photometry [32], the methodology of photometric image analysis during angular photometry by ellipsoidal reflector was improved. The processing scheme (Figure 4), except of region of interest and external ring A1, also contains ellipse of incident flux A2 and area of collimated reflection A3.…”
Section: Methods and Toolsmentioning
confidence: 99%
“…Based on the mechanism of image processing at ellipsoidal photometry [32], the methodology of photometric image analysis during angular photometry by ellipsoidal reflector was improved. The processing scheme (Figure 4), except of region of interest and external ring A1, also contains ellipse of incident flux A2 and area of collimated reflection A3.…”
Section: Methods and Toolsmentioning
confidence: 99%
“…The received photometric image is the precondition for further zone analysis in correspondence to its structure [37]. The photometer operating model interpretation suggests the forming the photometric images of reflector second focal plane as a Monte-Carlo simulation result of light propagation in system "multi-layered biological tissue + ellipsoidal reflector" [36]- [41].At the same time, the light source parameters in simulation are regulated by the software by means of setting the required photons quantity and cross section profile for the laser central mode during its operation in continues wave single-mode regime. Parameters of ellipsoid of revolution corresponds to real photometer reflector and have following values: eccentricity 0.66, focal parameter 16.875 mm, reflection coefficient 0.95.…”
Section: Methods and Toolsmentioning
confidence: 99%
“…The light scattering in both forward and back scattered directions during the photometry by ellipsoidal reflectors can be determined by the thickness of investigated BM sample [36], [37]. Table 2 represents the data of anatomic thickness of human skin layers, which were used during simulation for the different zones of photometric images illuminance estimation.…”
Section: Methods and Toolsmentioning
confidence: 99%
See 1 more Smart Citation
“…The using of ellipsoidal reflectors as a solution for increasing of specific weight of registered light during gathering of scattered light in the range of body angle 2π is successful. It proved its efficiency after interaction with rough surface of technical specimens [21], and optically turbid biological environments [22][23][24][25].…”
Section: Introductionmentioning
confidence: 97%