1926
DOI: 10.1152/ajplegacy.1926.76.2.247
|View full text |Cite
|
Sign up to set email alerts
|

The Nature and Time Relations of the Compression Sounds of Korotkov in Man

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
2

Year Published

1957
1957
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 0 publications
0
3
0
2
Order By: Relevance
“…In the early to mid-twentieth century Korns 36 and Groedel and Miller 37 published rare high speed time-domain tracings of Korotkoff sounds from normal human adults that clearly show transient damped sinusoidal waves. These actual sounds can be compared to modeled sounds as a point of validation.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the early to mid-twentieth century Korns 36 and Groedel and Miller 37 published rare high speed time-domain tracings of Korotkoff sounds from normal human adults that clearly show transient damped sinusoidal waves. These actual sounds can be compared to modeled sounds as a point of validation.…”
Section: Discussionmentioning
confidence: 99%
“…This detailed simulation study showed that flow pulses can contain sub-audible sonic information under realistic conditons. However, the sound is near 10 Hz, below the typical human threshold for hearing, and not near 70 Hz as demonstrated in vivo by high speed recordings 36,37 . This study may well have correctly rendered the low frequency and largely inaudible components of arterial sounds, but may it have missed the source of the higher frequency, sharper sounds that are used clinically to measure blood pressure by the ausculatatory method.…”
Section: Alternative Theoriesmentioning
confidence: 94%
“…Em 1926 Korns demonstrou que a freqüência dos sons de Korotkoff era influenciada pelo tamanho do manguito 16 . Essa descoberta foi corroborada em estudos realizados na década de 80 no Brasil , quando verificamos que a pressão de pulso registrada pelo manguito de largura correta para o braço era próxima à 40mmHg, versus cerca de 36mmHg nos registros com o manguito de largura padrão 17 O avanço no conhecimento na área da esfigmomanometria na década de 30 foi talvez o mais expressivo após as descobertas do início do século.…”
Section: A Esfigmomanometria Moderna Do Século Xx: Estudos Pós Korotk...unclassified
“…Using contemporary equipment and methods of data analysis, we have explored the feasibility of exploiting the temporal relationship between p-pulses and K-sounds, noted first by Korns [21], as a means of distinguishing between K-sounds and extraneous noise signals, and of recording the contours of arterial and volume pulses. Our study has revealed that both these aims can be realized without much difficulty.…”
Section: Introductionmentioning
confidence: 99%