2016
DOI: 10.1109/tdei.2015.004807
|View full text |Cite
|
Sign up to set email alerts
|

The natural contamination of XP-70 insulators in Shenzhen, China

Abstract: Equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) are two basic parameters for the coordination of outdoor insulation and classification of pollution severity. Type XP-70 is usually selected as the test object for classification of pollution distribution in China. In this study, 113 transmission towers representing typical distribution of Shenzhen, China, are selected as observation sites for XP-70 insulators, which have a total of four discs. The ESDD, NSDD and the ratio of NSDD to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
14
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 7 publications
2
14
0
Order By: Relevance
“…One major consequence of pollutants in such areas is the reduction of insulation or losing the insulation in transmission lines and stations. In such areas, an identification of an effective insulation in pollution scenarios is not only important for designing and selecting the appropriate type of insulation but also for adopting a proper maintenance plan of insulation devices . According to the literature, field visits, laboratory tests on insulators, computer simulation, and experience, there is a need for reconsidering insulation coordination in Mazandaran and Golestan power network.…”
Section: Statement Of the Problemmentioning
confidence: 99%
“…One major consequence of pollutants in such areas is the reduction of insulation or losing the insulation in transmission lines and stations. In such areas, an identification of an effective insulation in pollution scenarios is not only important for designing and selecting the appropriate type of insulation but also for adopting a proper maintenance plan of insulation devices . According to the literature, field visits, laboratory tests on insulators, computer simulation, and experience, there is a need for reconsidering insulation coordination in Mazandaran and Golestan power network.…”
Section: Statement Of the Problemmentioning
confidence: 99%
“…The fog was generated by a 1.5 t/h boiler, for which the rate was 0.05 ± 0.01 kg/h·m 3 . During the flashover test, the temperature in the chamber was maintained between 30 • C and 35 • C through control of the refrigeration system, and the atmospheric pressure was 98.6 kPa in all the experiments.…”
Section: Flashover Testmentioning
confidence: 99%
“…To sum up, insulator surface pollution is mainly made up of several conductive materials including NaCl, NaNO 3 , KCl, KNO 3 , Mg(NO 3 ) 2 , MgSO 4 , NH 4 NO 3 , NH 4 Cl, (NH 4 ) 2 SO 4 , Ca(NO 3 ) 2 , CaSO 4 , and other contaminants, according to the research data in [3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…The fog was generated by a 1.5 t/h boiler, of which the rate was 0.05 ± 0.01kg/h·m 3 . During flashover test, the temperature in the chamber was controlled between 30 ºC and 35 ºC through the refrigeration system and the atmospheric pressure is 98.6 kPa in all the experiments.…”
Section: Flashover Testmentioning
confidence: 99%
“…To sum up, insulator surface pollution is mainly made up of some conductive materials including NaCl, NaNO3, KCl, KNO3, Mg(NO3)2, MgSO4, NH4NO3, NH4Cl, (NH4)2SO4, Ca(NO3)2, CaSO4 et al according to the research data in [3][4][5].…”
Section: Introductionmentioning
confidence: 99%