2008
DOI: 10.1007/s00066-008-1878-3
|View full text |Cite
|
Sign up to set email alerts
|

The munich fission neutron therapy facility MEDAPP at the research reactor FRM II

Abstract: The clinical neutron irradiations of malignant tumors, which were performed at the former research reactor FRM until 2000, can be continued at FRM II under improved conditions. First patients were irradiated in June 2007.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 15 publications
(13 reference statements)
0
11
0
Order By: Relevance
“…The new treatment facility MedApp at FRM II offers a horizontal beam of unmoderated fission neutrons with a mean energy of 1.9 MeV Wagner et al, 2008). Compared to higher energy neutrons used at other neutron therapy facilities, fission neutrons show the highest linear energy transfer (LET) resulting in high biological effectiveness (RBE), but at the expense of low penetration depth (the 50% isodose is 5 cm deep in a water phantom).…”
Section: Methodsmentioning
confidence: 99%
“…The new treatment facility MedApp at FRM II offers a horizontal beam of unmoderated fission neutrons with a mean energy of 1.9 MeV Wagner et al, 2008). Compared to higher energy neutrons used at other neutron therapy facilities, fission neutrons show the highest linear energy transfer (LET) resulting in high biological effectiveness (RBE), but at the expense of low penetration depth (the 50% isodose is 5 cm deep in a water phantom).…”
Section: Methodsmentioning
confidence: 99%
“…In earlier measurements [ 1 , 30 ] the neutron and photon depth-dose curves in a water phantom were determined by a pair of thimble chambers with different neutron sensitivity that were irradiated at the patient position (EXTRADIN-chamber one out of tissue-equivalent (TE) material A150 with TE gas; sensitivity to neutrons/gamma = 48.5/51.5%; chamber two out of Mg/Ar, neutron sensitivity 2%, chamber volume: 0.5 cm 3 ). The phantom consisted of a box of Perspex filled with about 1701 of water with an entrance window for the horizontal beam and a device to position the ionization chambers.…”
Section: Methodsmentioning
confidence: 99%
“…In both geometries, the primary neutron and photon beam cross section was a square of 9 × 9 cm 2 , which is the same as the one used for the measurements [ 1 , 3 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This filtering is the standard one and mandatory for medical applications (MEDAPP beam); the fast neutron flux is 3.2×10 8 s -1 cm -2 . Further details are given in [1].…”
Section: Introductionmentioning
confidence: 99%