1969
DOI: 10.1088/0031-9155/14/1/311
|View full text |Cite
|
Sign up to set email alerts
|

The modulation transfer functions of x-ray focal spots

Abstract: A method is presented for the experimental determination of the modulation transfer functions of x-ray focal spots. The apparatus described is sufficiently flexible to permit the measurement of these functions under' various conditions of x-ray tube operation and at various positions and directions in a plane perpendicular to the direction of the x-ray beam. The results of measurements on four tubes used in the United States are discussed.Data on two tubes are given in detail with the theoretical functions exp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
10

Year Published

1972
1972
2017
2017

Publication Types

Select...
4
3
3

Relationship

0
10

Authors

Journals

citations
Cited by 21 publications
(13 citation statements)
references
References 3 publications
0
3
0
10
Order By: Relevance
“…1943 300 [25,26] 1950 4900 [27] 1951 2000 [28] 1955 2340 [29] 1955 3000 [29] 1956 300 [30] 1957 130 [31] 1957 300 [32] 1957 310 [31] 1957 1200 [33] 1958 400 [15] 1958 16000 [15] 1964 1000 [34] 1964 2000 [34] 1965 2000 [35] 1968 1000 [36] 1968 2000 [36] 1969 50 [37] 1969 340 [37] 1969 360 [38] 1969 500 [39] 1969 2000 [40] 1970 50 [41] 1970 300 [14] 1970 2000 [40] 1971 60 [42] 1971 270 [19] 1971 300 [42] 1971 1000 [42] 1972 2 2 1.0 [43] 1973 1000 1000 1.0 1 -3 √ [44] 1974 600 [45] 1974 2450 [45] 1975 148 [46] 1975 800 0.28 -2.54 [47] 1975 1490 [46] 1975 50 [48] 1977 15 [49] 1979 30 [50] 1980 15 [26] Table 1. X-ray detector sizes and focal spot sizes versus year published.…”
Section: Ct Referencementioning
confidence: 99%
“…1943 300 [25,26] 1950 4900 [27] 1951 2000 [28] 1955 2340 [29] 1955 3000 [29] 1956 300 [30] 1957 130 [31] 1957 300 [32] 1957 310 [31] 1957 1200 [33] 1958 400 [15] 1958 16000 [15] 1964 1000 [34] 1964 2000 [34] 1965 2000 [35] 1968 1000 [36] 1968 2000 [36] 1969 50 [37] 1969 340 [37] 1969 360 [38] 1969 500 [39] 1969 2000 [40] 1970 50 [41] 1970 300 [14] 1970 2000 [40] 1971 60 [42] 1971 270 [19] 1971 300 [42] 1971 1000 [42] 1972 2 2 1.0 [43] 1973 1000 1000 1.0 1 -3 √ [44] 1974 600 [45] 1974 2450 [45] 1975 148 [46] 1975 800 0.28 -2.54 [47] 1975 1490 [46] 1975 50 [48] 1977 15 [49] 1979 30 [50] 1980 15 [26] Table 1. X-ray detector sizes and focal spot sizes versus year published.…”
Section: Ct Referencementioning
confidence: 99%
“…Furthermore, parameters of the recording operation must be chosen so that the x-ray pattern is transferred with a minimum of degradation. The effect 6f many exposing parameters, such as focal spot [1][2][3][4][5][6] size and obiect posi tion, on the x-ray pattern are being studied.…”
mentioning
confidence: 99%
“…Função de transferência de fase (FTF) de um sistema isotrópico em duas direções, paralela e perpendicular ao eixo catodo-anodo. As linhas tracejadas indicam a FTF nas mesmas duas direções para um ponto focal perfeitamente quadrado (Rao & Bates, 1969) 3.8. Varredura densitométrica de uma imagem de fenda (Schiabel et al, 1997a)....... 3.10.…”
Section: Figura 34 (A)unclassified