1988
DOI: 10.1177/000456328802500514
|View full text |Cite
|
Sign up to set email alerts
|

The Middle East External Quality Assessment Scheme for Clinical Chemistry

Abstract: SUMMARY. The establishment and first 7 years' operation of an external quality assessment scheme for clinical chemistry in the Middle East region are described. The scheme utilises specimens distributed previously in the UK, and the performance of participating laboratories is assessed relative to the UK consensus values, taking account of method. Variance Index scoring has been used to quantitate performance, and there has been an improvement in average scores during the operation of the scheme. There are cur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

1989
1989
1993
1993

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…somewhat over the years, despite fluctuations brought about by the inclusion of new laboratories [3], and possible changes in composition of the control sera. The pattern of mean OMRVIS against time thus shows some improvement (Figure 3).…”
Section: Results and Conclusionmentioning
confidence: 99%
See 3 more Smart Citations
“…somewhat over the years, despite fluctuations brought about by the inclusion of new laboratories [3], and possible changes in composition of the control sera. The pattern of mean OMRVIS against time thus shows some improvement (Figure 3).…”
Section: Results and Conclusionmentioning
confidence: 99%
“…The organization of the scheme has been described elsewhere [2,3]. It is based on the scheme that has been operating successfully in the United Kingdom for over 20 years [2,4].…”
Section: Scheme Organizationmentioning
confidence: 99%
See 2 more Smart Citations
“…The mean CVs for these EQA schemes were calculated for the same period as the present study. 3 In general there was greater inter-laboratory variation in Jordan than in the other schemes In the first study, standard solutions of glucose, urea and cholesterol, 'covering normal and abnormal ranges, were distributed on two occasions. The recalculated CVs obtained in these two trials were II· 48% and 12 '100/0 for glucose, 14· 73% and 16· 01 % for urea and 11' 89% for cholesterol, well within the corresponding ranges obtained for control sera (Table 3).…”
Section: Specific Investigationsmentioning
confidence: 99%