The Method to Determine the Turns Ratio Correction of the Inductive Current Transformer

Abstract: This paper presents the method for evaluation of the turns ratio correction of the inductive current transformer using the magnetization curves determined at the non-load state and in the load conditions. The presented method may be applied to determine even a fractional winding correction factor. The standard IEC 61869-2 provides the method to determine the turns ratio correction of the tested CT from the measured rms values of voltages on its primary and secondary winding in the non-load state. However, this… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 27 publications
0
13
0
Order By: Relevance
“…In these conditions, the highest current error values occurred for 120% I 1N and 25% S N . Moreover, the applied correction of turns of the secondary winding caused a shift of the current error value in a positive direction [26]. As the load on the secondary winding increased, the current error values moved toward a negative value.…”
Section: Metrological Performance Of the Cts In A Wide Frequency Rangementioning
confidence: 97%
See 1 more Smart Citation
“…In these conditions, the highest current error values occurred for 120% I 1N and 25% S N . Moreover, the applied correction of turns of the secondary winding caused a shift of the current error value in a positive direction [26]. As the load on the secondary winding increased, the current error values moved toward a negative value.…”
Section: Metrological Performance Of the Cts In A Wide Frequency Rangementioning
confidence: 97%
“…In other cases, its primary winding must be fed by a rated current, which may be generated by a step-up current transformer with a wideband power amplifier [22][23][24]. The results and analysis in [25] are helpful to understand the course of the wideband metrological characteristics of a corrected inductive CT [26]. The proposed vectorial diagrams define the components conditioning the values of the current error and phase displacement of the harmonic of the specified distorted current.…”
Section: Introductionmentioning
confidence: 99%
“…Also, for the decreased load of the secondary winding, the high me performance of the ICT 1 is retained. The positive values of current error deter ICT 2 results from applied turns number correction, where the real turns ratio is to the rated current ratio [30]. The ICT 1 is not corrected.…”
Section: Metrological Performance Of the Cts In The Wide Frequencies ...mentioning
confidence: 99%
“…There are two common methods for achieving decimal-turn windings [16]. One method is to wind multiple wires in parallel, but the turns of different wires may be one turn different, so that the number of equivalent secondary turns will be a decimal or a fraction.…”
Section: Turns Ratio In Appropriate Less Than Current Ratio Achieves ...mentioning
confidence: 99%