The Metabolomics Workbench File Status Website: A Metadata Repository Promoting FAIR Principles of Metabolomics Data

Abstract: Motivation: An updated version of the mwtab Python package for programmatic access to the Metabolomics Workbench (MetabolomicsWB) data repository was released at the beginning of 2021. Along with updating the package to match the changes to MetabolomicsWB's 'mwTab' file format and to enhance the package's functionality, the package included format validation facilities which were used to detect and catalog file inconsistencies and errors across all publically available datasets in MetabolomicsWB. Results: The … Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
3

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…The result of this research was verified by the sampling result generated by the Kentucky Department of Environmental Protection Agency (KDEP) [28]. KDEP sampled eighty-one (81) public drinking water systems, of which forty-three (43) are surface water sources and thirty-eight (38) are groundwater sources. In 2019, KDEP directly tested for eight (8) PFAS, including Perfluorobutane sulfonate (PFBS), Hexafluoropropylene oxide-dimer(HFDO-DA or Gen-X), perfluoroheptanoic acid (PFHpA), Perfluorohexane sulfonate (PFHxS), Ammonium 4,8-dioxa-3Hperfluorononanoate (ADONA), PFOA, PFOS, and Perfluorononanoic acid (PFNA) [29].…”
Section: Background and Summarymentioning
confidence: 61%
See 2 more Smart Citations
“…The result of this research was verified by the sampling result generated by the Kentucky Department of Environmental Protection Agency (KDEP) [28]. KDEP sampled eighty-one (81) public drinking water systems, of which forty-three (43) are surface water sources and thirty-eight (38) are groundwater sources. In 2019, KDEP directly tested for eight (8) PFAS, including Perfluorobutane sulfonate (PFBS), Hexafluoropropylene oxide-dimer(HFDO-DA or Gen-X), perfluoroheptanoic acid (PFHpA), Perfluorohexane sulfonate (PFHxS), Ammonium 4,8-dioxa-3Hperfluorononanoate (ADONA), PFOA, PFOS, and Perfluorononanoic acid (PFNA) [29].…”
Section: Background and Summarymentioning
confidence: 61%
“…Even with minimum standards, deposition quality is a constant issue that hinders FAIRness [41][42][43]. For research data types that have no procedures or minimum standards, these problems are far worse.…”
Section: Background and Summarymentioning
confidence: 99%
See 1 more Smart Citation
“…As far as CloMet FAIRness is concerned, CloMet inherits the FAIR principles of the data coming from Metabolights and Metabolomics Workbench. These two repositories already promote FAIR principles. , Thus, CloMet does not add any new indexing scheme nor modifies any file format, but it just adopts the data properties of its sources. Our custom data format is an internal standard that harmonizes the different formats found in public repositories.…”
Section: Discussionmentioning
confidence: 99%
“…Given the lack of need for proprietary software to export pixel-by-pixel data, an individual feature list provides MALDI-MS instrument/application flexibility. Additionally, considering each pixel data as a replicate from a defined ROI, exported pixel data can also be used for multivariate spatial metabolomics data analysis using either vendor-specific or non-proprietary metabolomics data software platforms [27][28][29][30][31][32][33][34][35][36][37][38][39] . Figure S1 shows an exemplary conversion of ROI pixel data to formats compatible with import into MetaboAnlayst 27 and Agilent Mass Hunter Professional, allowing for multivariate statistical analysis and biomarker discovery.…”
mentioning