2018
DOI: 10.1016/j.apsusc.2018.01.065
|View full text |Cite
|
Sign up to set email alerts
|

The matrix effect in secondary ion mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(21 citation statements)
references
References 32 publications
0
21
0
Order By: Relevance
“…Matrix-assisted laser desorption ionization uses a laser energy absorbing matrix to create ions from large molecules with minimal fragmentation . Secondary ion MS generates ions that are then transferred into a mass spectrometer across a high electrostatic potential and are referred to as secondary ions . Desorption spectrometry observes desorbed molecules from a surface when the surface temperature is increased .…”
Section: Technology Of Metabolomicsmentioning
confidence: 99%
“…Matrix-assisted laser desorption ionization uses a laser energy absorbing matrix to create ions from large molecules with minimal fragmentation . Secondary ion MS generates ions that are then transferred into a mass spectrometer across a high electrostatic potential and are referred to as secondary ions . Desorption spectrometry observes desorbed molecules from a surface when the surface temperature is increased .…”
Section: Technology Of Metabolomicsmentioning
confidence: 99%
“…Indeed, the local structure and chemical composition of the matrix material influences the intensity of the emitted secondary ion regardless of the actual element concentration. 22,26 Another limitation of the curvature technique is the differences in inter-diffusion of elements between the enamel and the glass substrates, having different composition. Additionally, the glass transition temperature of the CS77 substrate is 90°C higher than the V95 substrate.…”
Section: Discussionmentioning
confidence: 99%
“…This is because the sample matrix influences the ionization probability of analytes, resulting in enhancement or suppression of the signal intensity [77]. These matrix effects are more severe for organic compounds where protonation and charge transfer processes occur [78]. This can be mitigated to some extent by chemical modification of the sample [79] or by coating the sample surface with a layer of matrix prior to MSI experiments.…”
Section: Analysis Of Hair By Mass Spectrometry Imagingmentioning
confidence: 99%