2020
DOI: 10.1111/psyp.13580
|View full text |Cite
|
Sign up to set email alerts
|

The Maryland analysis of developmental EEG (MADE) pipeline

Abstract: Compared to adult EEG, EEG signals recorded from pediatric populations have shorter recording periods and contain more artifact contamination. Therefore, pediatric EEG data necessitate specific preprocessing approaches in order to remove environmental noise and physiological artifacts without losing large amounts of data. However, there is presently a scarcity of standard automated preprocessing pipelines suitable for pediatric EEG.In an effort to achieve greater standardization of EEG preprocessing, and in pa… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
125
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
4

Relationship

3
7

Authors

Journals

citations
Cited by 136 publications
(139 citation statements)
references
References 22 publications
1
125
0
Order By: Relevance
“…Electroencephalography was analyzed using the EEGLAB toolbox (Delorme & Makeig, 2004), MATLAB scripts (The MathWorks), and the MADE pipeline (Debnath et al, 2020). Data were high-pass filtered at 0.3 Hz and low-pass filtered at 50 Hz.…”
Section: Eeg Collection and Analysismentioning
confidence: 99%
“…Electroencephalography was analyzed using the EEGLAB toolbox (Delorme & Makeig, 2004), MATLAB scripts (The MathWorks), and the MADE pipeline (Debnath et al, 2020). Data were high-pass filtered at 0.3 Hz and low-pass filtered at 50 Hz.…”
Section: Eeg Collection and Analysismentioning
confidence: 99%
“…During data collection, electrodes were referenced to electrode Cz. All pre-processing, including ocular artifact detection and removal, was performed with the Maryland Analysis of Developmental EEG (MADE) pipeline (Debnath et al, 2020), which utilizes MATLAB (The MathWorks, Natick, MA) functions from EEGLAB (Delorme & Makeig, 2004) and its plugins "FASTER" (Nolan et al, 2010), "ADJUST" (Mognon et al, 2011), and "ADJUSTED ADJUST" (Leach et al, 2020). Offline, data were re-referenced to an average reference and band-pass filtered from 0.3 to 50 Hz with a digital FIR filter.…”
Section: Screen For Child Anxiety Related Emotional Disordersmentioning
confidence: 99%
“…EEG from all three studies were recorded using a 128-channel HydroCel Geodesic Sensor Net (Electrical Geodesics, Inc., Eugene, OR). The data acquisition, preprocessing, timefrequency, and spectral power analysis procedures are detailed in supplementary analyses and followed the Maryland Analysis of Developmental EEG (MADE) pipeline (Debnath et al, 2020). Frontal alpha asymmetry.…”
Section: Eeg Data Acquisition and Processingmentioning
confidence: 99%