2012
DOI: 10.1088/1748-0221/7/02/c02063
|View full text |Cite
|
Sign up to set email alerts
|

The ITER divertor Thomson scattering system: engineering and advanced hardware solutions

Abstract: A divertor Thomson scattering (TS) system being developed for ITER has incorporated proven solutions from currently available TS systems. On the other hand any ITER diagnostic has to operate in a hostile environment and very restricted access geometry. Therefore the operation in an environment of intensive stray light, plasma background radiation, the necessity meet the requirement using only a 20 mm gap between divertor cassettes for plasma diagnosis as well as to measure plasma temperatures as low as 1 eV se… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 10 publications
0
7
0
1
Order By: Relevance
“…The in-vessel collection optics have been designed simultaneously with neutron shielding to meet the following criteria normalized to 500 MW of fusion power: in-vessel optics temperature 250 C; residual radioactivity 12 days after reactor shutdown 100 µSv h −1 allowing manned service/maintenance activities in the port cell (to the right of closure plate in figure 2); contribution from the divertor to equatorial port cell 10 µSv h −1 ; energy release 2 × 10 −3 W cm −3 in the toroidal field coil and PF coil jacket walls neighbouring the divertor port. The efficiency of the neutron shield design was presented in [6].…”
Section: Dts General Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…The in-vessel collection optics have been designed simultaneously with neutron shielding to meet the following criteria normalized to 500 MW of fusion power: in-vessel optics temperature 250 C; residual radioactivity 12 days after reactor shutdown 100 µSv h −1 allowing manned service/maintenance activities in the port cell (to the right of closure plate in figure 2); contribution from the divertor to equatorial port cell 10 µSv h −1 ; energy release 2 × 10 −3 W cm −3 in the toroidal field coil and PF coil jacket walls neighbouring the divertor port. The efficiency of the neutron shield design was presented in [6].…”
Section: Dts General Descriptionmentioning
confidence: 99%
“…The triple grating polychromator was described in [6] has a high degree of discrimination against stray light at the laser wavelength and was designed to measure very narrow TS spectra corresponding to T e from 0.3 eV to several hundred eV. For the upper part of the TS probing chord with T e from ∼5 eV to several 1000 eV (possible during transient events), a filter polychromator with separation of TS and LIF signals has been developed to allow the diagnostics to be combined.…”
Section: Dts General Descriptionmentioning
confidence: 99%
“…The suggested solution is to use triple-grating polychromator for measurements of the lower part of the chord [22]. Figure 24 illustrates the comparison of the spectral channels distribution for the grating spectrometer against the filter polychromator.…”
Section: Very Low Temperaturementioning
confidence: 99%
“…Параметры лазера Nd:YAG, который будет использоваться в системе [6,7] Первое испытание этого лазера будет проводиться в составе диагностики томсоновского рассеяния на установке Т-10.…”
Section: лазерunclassified