2010
DOI: 10.1109/tasc.2010.2040149
|View full text |Cite
|
Sign up to set email alerts
|

The Iseult/Inumac Whole Body 11.7 T MRI Magnet R&D Program

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 11 publications
0
14
0
Order By: Relevance
“…The reduced operating temperature is achieved using a pump running continuously on the helium reservoir (Warner 2008). As a part of the French- n/a n/a n/a n/a German research project Iseult/INUMAC the design and manufacture of an actively shielded 11.7 T with a 90 cm bore is advancing (Vedrine et al 2008 and references therein; Schild et al 2010). The magnet system will be built by CEA/Dapnia/Irfu.…”
Section: T Mri Magnetsmentioning
confidence: 99%
See 1 more Smart Citation
“…The reduced operating temperature is achieved using a pump running continuously on the helium reservoir (Warner 2008). As a part of the French- n/a n/a n/a n/a German research project Iseult/INUMAC the design and manufacture of an actively shielded 11.7 T with a 90 cm bore is advancing (Vedrine et al 2008 and references therein; Schild et al 2010). The magnet system will be built by CEA/Dapnia/Irfu.…”
Section: T Mri Magnetsmentioning
confidence: 99%
“…The main coil is built up from an arrangement of modules of double pancake windings. This configuration allows direct contact of the superconductor with super fluid helium (T = 1.8 K) and thus the system benefits from cryostabilization (Vedrine et al 2008;Schild et al 2010). …”
Section: T Mri Magnetsmentioning
confidence: 99%
“…Use of filtering components, e.g. like that used by the 11.7 tesla Iseult circuit [22] may help alleviate cost increase from the high quality power supply.…”
Section: Conductor Requirements Challenges and Opportunitiesmentioning
confidence: 99%
“…With the pancake approach, one can see a potential of coil topology switching from the traditional 8-coil multi-coil design to multiple pancakes or pancake blocks. In order to deliver required homogeneity, such pancakes/blocks would be strategically distributed axially, spaced apart and separated by spacers that support inter-pancake forces [22], [29]. …”
Section: Conductor Requirements Challenges and Opportunitiesmentioning
confidence: 99%
“…The system is designed to operate in non-persistent mode in a bath of superfluid LHe, which is serviced by a separate cryogenic facility forming an integral part of the installation. The design and supporting R&D were completed in 2013 [2], [3] and the project is now in the realisation phase.…”
Section: Introductionmentioning
confidence: 99%