2020
DOI: 10.1007/s00590-020-02738-8
|View full text |Cite|
|
Sign up to set email alerts
|

The inverted Vancouver C fracture. Case series of unstable proximal femur fractures above a knee revision stem treated by short cephalomedullary nail and lateral submuscular overlapping plate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…The complex scenario of an inter-prosthetic fracture has pushed some authors to use overlapping prophylactic plates. Peiró et al treated unstable proximal femur fractures above a knee revision stem with a combination of a short nail and an overlapping lateral plate and resulted in a 100% bone healing and well tolerated early weight bearing without records of major local complications ( 44 ). Campillo-Recio et al also concluded that, instead of treating such complex fractures, they preferred an effective, safe and reproducible preventive surgical approach, which would involve internal femoral splinting and a prophylactic plate ( 45 ).…”
Section: Discussionmentioning
confidence: 99%
“…The complex scenario of an inter-prosthetic fracture has pushed some authors to use overlapping prophylactic plates. Peiró et al treated unstable proximal femur fractures above a knee revision stem with a combination of a short nail and an overlapping lateral plate and resulted in a 100% bone healing and well tolerated early weight bearing without records of major local complications ( 44 ). Campillo-Recio et al also concluded that, instead of treating such complex fractures, they preferred an effective, safe and reproducible preventive surgical approach, which would involve internal femoral splinting and a prophylactic plate ( 45 ).…”
Section: Discussionmentioning
confidence: 99%
“…This can be obtained using longer plates, with well-spaced screws, that span the whole femoral diaphysis, thereby increasing flexibility while avoiding stress risers that may jeopardize peri-implant fractures ( Figure 3B ); and a hybrid fixation technique with locking screws in the metaphyseal area and non-locking screws in the diaphysis [ 11 ]. Compared to the eight-cortex fixation approach around the stem that Ruchholtz et al described [ 6 ], we aimed for at least six cortices ( Figure 3C ), considering the results reported previously by Peiró et al with this implant while treating unstable proximal femur fractures above a knee revision stem [ 19 ]. In most of our patients, cerclage wiring was used as a reduction tool and not fixed to the plate.…”
Section: Discussionmentioning
confidence: 99%