IUPAC Standards Online 2016
DOI: 10.1515/iupac.78.0001
|View full text |Cite
|
Sign up to set email alerts
|

The International Harmonized Protocol for the Proficiency Testing of Analytical Chemistry Laboratories

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
88
1
34

Year Published

2016
2016
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 80 publications
(125 citation statements)
references
References 17 publications
2
88
1
34
Order By: Relevance
“…Therefore, either correction factor can be used to quantify these FAs in edible vegetable oils, as stated by Mosoba and Kramer (2009), and confirmed from the values calculated using both correction factors (p>0.05). Z score results were satisfactory according to Thompson et al (2006). All the mean values for the seven certified FAMEs were ≤2 z, which confirms the homo genity of these results.…”
Section: Bcr-163 Certifi Ed Reference Materialssupporting
confidence: 70%
See 1 more Smart Citation
“…Therefore, either correction factor can be used to quantify these FAs in edible vegetable oils, as stated by Mosoba and Kramer (2009), and confirmed from the values calculated using both correction factors (p>0.05). Z score results were satisfactory according to Thompson et al (2006). All the mean values for the seven certified FAMEs were ≤2 z, which confirms the homo genity of these results.…”
Section: Bcr-163 Certifi Ed Reference Materialssupporting
confidence: 70%
“…In the five laboratories, the z score was calculated for each one of the seven certified FAMEs of the reference certified material BCR 163, using their respective calculated ECF, according to IUPAC (Thompson et al, 2006). ANOVA statistical analysis at 95% confidence was used for testing if there were significant differences among the values obtained for the certified FAMEs using ECF and TCFr and applying the Statgraphics Plus 5.1 statistical program.…”
Section: Discussionmentioning
confidence: 99%
“…Homogeneity and stability were examined from the means and relative standard deviations by (1) comparisons with predefined tolerances, (2) Cochran′s test [1,4], and (3) a one-way ANOVA test [5,6].…”
Section: Methodsmentioning
confidence: 99%
“…Appropriate statistical techniques should be used to evaluate homogeneity testing data. One suitable approach is the International Harmonized Protocol for the Proficiency Testing of (Chemical) Analytical Laboratories, cooperatively produced by ISO and IUPAC [1].…”
Section: Introductionmentioning
confidence: 99%
“…Los ensayos de aptitud de macronutrientes constituyen una herramienta indispensable en la validación de los métodos analíticos [41][42][43] . El valor HORRAT, definido como la relación entre la desviación estándar de la reproducibilidad y la función de Horwitz (s R /H), muestra que los valores hallados se encuentran en el intervalo 0,5<Hs R <2.0 44 , lo que indica que los procedimientos de ensayo tienen una veracidad satisfactoria.…”
Section: Validación De Procedimientos Analíticosvunclassified