The Influence of the Steam-side Characteristics of a Modular Air- cooled Condenser on CSP Plant Performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 6 publications
(6 reference statements)
0
9
0
Order By: Relevance
“…An example of such pressure data is given in Fig. 3, which is an extract of data, at one particular flow rate, which was previously published in O'Donovan et al [28]. Data at other flow rates is omitted here for clarity.…”
Section: Data Processing Of Test Resultsmentioning
confidence: 97%
See 2 more Smart Citations
“…An example of such pressure data is given in Fig. 3, which is an extract of data, at one particular flow rate, which was previously published in O'Donovan et al [28]. Data at other flow rates is omitted here for clarity.…”
Section: Data Processing Of Test Resultsmentioning
confidence: 97%
“…A brief description of the experimental arrangement is presented followed by an overview of the measurement procedure and experimental uncertainty. Further details are available in previously published papers by the authors in O'Donovan et al [27] and O'Donovan et al [28].…”
Section: Methodsmentioning
confidence: 95%
See 1 more Smart Citation
“…In 1984, Eskom ordered air-cooled condensers for the Majuba power plant (6 x 660 MWe). It was then put into operation in 1996 and of the six units in the power plant, only three units were finally equipped with air-cooled condensers [8].…”
Section: Historymentioning
confidence: 99%
“…Du et al [28] found that the heat transfer coefficient of steam condensation inside a copper tube remains virtually constant with the increasing steam velocity at the tail of the tube, which has a diameter of 25 mm and temperature difference equal to two degrees between the saturated steam the coolant media. OˊDonovan et al [29] submitted a thermal analysis to determine the outputs of erecting an ACC in concentrated solar power. Steam condenser temperature and correspondence pressure have been measured as a function of fan speed, which varied (changing the air volumetric flow rates) at steam mass flow rates.…”
Section: Introductionmentioning