2014
DOI: 10.1111/jopr.12144
|View full text |Cite
|
Sign up to set email alerts
|

The Influence of Interimplant Divergence on the Retention Characteristics of Locator Attachments, a Laboratory Study

Abstract: The retention of Locator pairs was not impaired by interimplant divergence of up to 20°. Retention after 5500 removal cycles was less than the initial retention in all groups. The nylon Locator patrices showed wear defects of similar location, type, and magnitude in the SEM images, regardless of interimplant angulation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
84
0
3

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(92 citation statements)
references
References 20 publications
4
84
0
3
Order By: Relevance
“…Moreover, Locator abutments feature internal and external undercuts, which resist removal of the resilient patrix insert. If the matrix abutment is not identically aligned to the removal path of the patrix insert, large undercuts are created on the mesial and distal sides of the angled implants (22). These undercuts increase in size as the degree of implant angulation increases.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, Locator abutments feature internal and external undercuts, which resist removal of the resilient patrix insert. If the matrix abutment is not identically aligned to the removal path of the patrix insert, large undercuts are created on the mesial and distal sides of the angled implants (22). These undercuts increase in size as the degree of implant angulation increases.…”
Section: Discussionmentioning
confidence: 99%
“…The effect of distal (21)(22)(23) and mesial (24,25) inclinations of two-implant-retained overdentures with Locator attachments have been investigated. However, data regarding peri-implant strain around two-inclined implant-retained overdentures remain scarce (17,(26)(27)(28).…”
Section: Introductionmentioning
confidence: 99%
“…The "female" matrix is a cylindrical abutment coated with titanium nitride that has internal and external undercuts. 10 Different factors contribute to the success of an implant supported overdenture, including the fitness and precision of dentures and the retentive scope of its attachment system to provide long-term functionality. 12,20 In addition, retention could be one of the most serious factors in determining patient satisfaction.…”
Section: Jcdpmentioning
confidence: 99%
“…의치 가 하루 3, 4회 착탈이 반복된다는 가정 하에 2년에 해당하 는 2,500회의 착탈을 반복하였다 23) . 각 어태치먼트의 유지 력을 초기와 100, 250, 500, 1,000, 2,000, 2,500회마다 3회 씩 측정하여 그에 따른 평균값을 이용하였다.…”
Section: 유지력 변화 측정unclassified
“…임플란트 사이의 간격도 유지력에 영향을 미칠 수 있기 때문 에 하악의 두 견치 간 평균 거리인 22 mm로 간격을 통일하 였다 23,26) . 그 외에도 어태치먼트의 힘의 방향, 각도, 착탈시의 속도 등의 실험 조건에 따라 유지력의 차이를 보이므로, crosshead speed는 환자의 평균 의치제거 속도인 60 mm/min으로 설정하고 힘의 방향은 수직으로 적용하였다 21,23) .…”
Section: The Deformed Edge Of Kerator Red Matrix (E F) Deterioratedunclassified