2019
DOI: 10.1080/16878507.2019.1707400
|View full text |Cite
|
Sign up to set email alerts
|

The influence of increment of gantry on VMAT plan quality for cervical cancer

Abstract: This study aimed to assess the influence of increment of gantry (IG) value on plan quality among cervical cancer patients treated with volumetric modulated arc therapy (VMAT). Twenty postoperative cervical cancer patients receiving radiotherapy were selected. Four different VMAT plans were designed in Monaco TPS using the same optimization conditions but with varying IG parameters (10°, 20°, 30°, and 40°). The IG10 group did not meet the clinical requirements. The target dose of the IG20 group was slightly wor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 19 publications
(19 reference statements)
2
9
0
Order By: Relevance
“…Two coplanar full arcs rotating in clockwise and anticlockwise directions were used. The segment width was set to 1.0 cm 15 and the increment of gantry was 30° 16 . All VMAT plans were designed to satisfy the dose constraints introduced by the RTOG 0418 for modulated radiotherapy 17 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Two coplanar full arcs rotating in clockwise and anticlockwise directions were used. The segment width was set to 1.0 cm 15 and the increment of gantry was 30° 16 . All VMAT plans were designed to satisfy the dose constraints introduced by the RTOG 0418 for modulated radiotherapy 17 .…”
Section: Methodsmentioning
confidence: 99%
“…The segment width was set to 1.0 cm 15 and the increment of gantry was 30°. 16 All VMAT plans were designed to satisfy the dose constraints introduced by the RTOG 0418 for modulated radiotherapy. 17 These constraints are summarized in Table 1.…”
Section: B | 3d-crt and Vmat Planningmentioning
confidence: 99%
“…Over the last decade, IMRT has been a major field of research in the treatment of nasopharyngeal carcinoma (NPC) owing to its dosimetric advantages ( Guo et al., 2021 ; Lee et al., 2012 ; Sayah et al., 2020 ). In automatic IMRT optimization, the quality and efficiency of plan are closely associated with a number of different parameters ( Pakela et al., 2020 ; Burmeister et al., 2004 ; Chen et al., 2020 ; Wang et al., 2018 ). The general approach for this technique is to broke up each beam into several beamlets, which are small units that can be modulated with the aid of a computer program.…”
Section: Introductionmentioning
confidence: 99%
“…An NPC IMRT plan usually includes hundreds of segments. The setting of the optimization parameters, such as gantry angle increment and minimum segment width, during planning affects the dose distribution and the delivery efficiency of the radiotherapy plan, thereby affecting plan quality (Chen et al, 2019;Wang et al, 2018). The number of control points in the IMRT plan determines the number of segments; an increase in the number of control points results in an increase in the number of segments and the degrees of freedom for plan modulation, thus improving plan quality.…”
Section: Introductionmentioning
confidence: 99%