2015
DOI: 10.1109/tpwrd.2014.2386276
|View full text |Cite
|
Sign up to set email alerts
|

The Influence of Geomagnetic Storms on Thermal Processes in the Tank of a Power Transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0
3

Year Published

2017
2017
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 3 publications
0
4
0
3
Order By: Relevance
“…Процесс насыщения вызывает изменение картины распределения магнитных потоков по элементам магнитной системы силового трансформатора, следствием которого является увеличение потоков рассеяния и токов намагничивания. Последний приобретает однополярный характер и служит источником интенсивных высших гармоник тока [6].…”
Section: / 63 and Tdts-400000/242/20 The Dependences Of The Mean Vaunclassified
See 1 more Smart Citation
“…Процесс насыщения вызывает изменение картины распределения магнитных потоков по элементам магнитной системы силового трансформатора, следствием которого является увеличение потоков рассеяния и токов намагничивания. Последний приобретает однополярный характер и служит источником интенсивных высших гармоник тока [6].…”
Section: / 63 and Tdts-400000/242/20 The Dependences Of The Mean Vaunclassified
“…то условие Неймана будет выполняться на окружности радиуса r 0 (μ d(S) = 1) , если положить константы c 0 , c 1 равными(6) …”
unclassified
“…The DC bias result in abnormal vibration, noise, harmonics, reactive power loss and temperature rise [7]. As for the influence of geomagnetic storms, in addition to the blackout [8], there have been a large number accidents where transformers were severely damaged due to the temperature rise [9][10][11]. In reference [9], where the accident on March 13, 1989 has been introduced, geomagnetic storms encroached New Jersey Salem nuclear power plant and caused damage to the 500kV/1200MVA transformer.…”
Section: Introductionmentioning
confidence: 99%
“…The accident caused by the GIC in South African Power Grid destroyed several 400 kV transformers during the geomagnetic storms in October to November, 2003 [10]. In reference [11], the tank model of the transformer leakage flux distribution and the temperature rise was established, and the values of leakage flux and temperature rise were calculated. The previous researches on the transformer temperature rise due to GIC are very limited for the probable reasons that the GIC does not exist in all countries and the transformer designing is related to commercial secrets.…”
Section: Introductionmentioning
confidence: 99%
“…This also causes a corresponding increase in temperatures. Some very recent papers have focused on the heating of the various parties of the transformer [4,10,11]. When unipolar half-wave saturation of the transformer core occurs, a larger portion of the flux no longer passes through the core, which has the effect of creating additional eddy currents on the transformer core clamping bolts, the winding, the tie plates and the tank walls.…”
Section: Introductionmentioning
confidence: 99%