2020
DOI: 10.1007/s10396-020-01024-8
|View full text |Cite
|
Sign up to set email alerts
|

The influence of esophagogastroduodenoscopy using carbon dioxide insufflation on abdominal ultrasonographic imaging efficiency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(13 citation statements)
references
References 10 publications
0
13
0
Order By: Relevance
“…Two trials associated with this hypothesis have been reported. As only a limited number of organs were available for observation by AUS and the statistical analysis was inadequate in these trials, the results of data analyses are insu cient to prove our hypothesis, and they showed partially negative results 3 or results that partially exceeded this hypothesis 4 . To prove this hypothesis, we designed a non-inferiority test 5 that compared image quality of AUS performed following EGD with CO 2 insu ation (post-EGD AUS) with that of AUS prior to EGD (pre-EGD AUS) in the same subject.…”
Section: Introductionmentioning
confidence: 77%
See 2 more Smart Citations
“…Two trials associated with this hypothesis have been reported. As only a limited number of organs were available for observation by AUS and the statistical analysis was inadequate in these trials, the results of data analyses are insu cient to prove our hypothesis, and they showed partially negative results 3 or results that partially exceeded this hypothesis 4 . To prove this hypothesis, we designed a non-inferiority test 5 that compared image quality of AUS performed following EGD with CO 2 insu ation (post-EGD AUS) with that of AUS prior to EGD (pre-EGD AUS) in the same subject.…”
Section: Introductionmentioning
confidence: 77%
“…However, the mean image quality was reduced for all organs. Nakagawara et al 4 reported that using CO 2 insu ation instead of air improved the image quality of AUS at 60 min after EGD in some patients. They used a three-point Likert scale of better, unchanged, and worse for evaluation of image quality of AUS after EGD, compared with that of AUS images before EGD as control.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Two trials associated with this hypothesis have been reported. As only a limited number of organs, such as the pancreas alone 3 or the pancreas, extrahepatic bile duct, and inferior pole of the right kidney 4 , were available for observation by AUS, and the statistical analysis was inadequate in these trials in which no statistical analysis was done 3 or a signi cant difference test was done instead of a non-inferiority test 4 , the results of the data analyses are insu cient to test our hypothesis. In addition, they reported partially negative results 3 showing that, in about 27% of patients, the image quality of AUS was worse 3 .…”
Section: Introductionmentioning
confidence: 90%
“…In addition, they reported partially negative results 3 showing that, in about 27% of patients, the image quality of AUS was worse 3 . However, they also reported results based on which they concluded that the image quality of AUS was improved in some patients 4 .To prove this hypothesis, we designed a non-inferiority test 5 that compared image quality of AUS performed following EGD with CO 2 insu ation (post-EGD AUS) with that of AUS prior to EGD (pre-EGD AUS) in the same subject.…”
Section: Introductionmentioning
confidence: 99%