2004
DOI: 10.1016/s0143-8166(02)00213-0
|View full text |Cite
|
Sign up to set email alerts
|

The influence of diffraction in microinterferometry and microtomography of optical fibers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Use of a developed commercial interference microscope, as opposed to implementation of a bulk optic interferometer, 18 offers several advantages for conducting this type of measurement. Interference microscopes, such as the Mach-Zehnder transmittedlight system discussed in Section 4, are designed to have precise, stable optical elements that minimize wave-front distortion and maintain path balance and thereby increase interference-image stability.…”
Section: Measurement Optimization For Characterizing Small Asymmetric...mentioning
confidence: 99%
See 2 more Smart Citations
“…Use of a developed commercial interference microscope, as opposed to implementation of a bulk optic interferometer, 18 offers several advantages for conducting this type of measurement. Interference microscopes, such as the Mach-Zehnder transmittedlight system discussed in Section 4, are designed to have precise, stable optical elements that minimize wave-front distortion and maintain path balance and thereby increase interference-image stability.…”
Section: Measurement Optimization For Characterizing Small Asymmetric...mentioning
confidence: 99%
“…Ray tracing offers one method for investigating whether a particular optical fiber sample would introduce too much deviation. 18,27 Consistent with the primary purpose of detecting small variations in refractive index, several portions of the measurement and analysis procedures can be changed within the reconstruction process to lower noise levels and subsequently improve detection of small variations in refractive index. Taking projections over a full 360°, taking additional projections, and employing various reconstruction filters all act to lower noise levels in certain regions of reconstructed objects.…”
Section: Measurement Optimization For Characterizing Small Asymmetric...mentioning
confidence: 99%
See 1 more Smart Citation
“…The resolution values of the technique are estimated and depend on many factors (CCD array size, resolving power, beam deflection, source wavelength, etc.). 8,9 In summary, we have presented the first, to our knowledge, nondestructive measurements of optical fiber refractive-index profiles obtained with MIOPT. The example measured profiles demonstrate experimentally the ability of MIOPT to profile both azimuthally asymmetric and symmetric optical fibers or fiber devices.…”
mentioning
confidence: 97%
“…In case presented below 180 frames were taken (rotation step ∆α=1°), phase reconstruction for each interferogram. 2D map o refractive index is done with 5 points spatial carrier phase shifting algorithm [10], calculation of 3D distribution of refractive index (modified filtered back projection method [11]). …”
Section: Methodsmentioning
confidence: 99%