The Influence of Alteration of kVp and mAs towards the Image Quality of Acrylic Using CBCT

Abstract: CBCT is a modernized technology in producing radiograph image on dentistry. The image quality excellence is very important for clinicians to interpret the image, so the result of diagnosis produced becoming more accurate, appropriate, thus minimizing the working time. This research was aimed to assess the image quality using the blank acrylic phantom polymethylmethacrylate (PMMA) (C­5H8O2)n in the density of 1.185 g/cm3 for evaluating the homogeneity and uniformity of the image produced. Acrylic phantom was su… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…The presence of posts within the root canal generates artifacts, which may hinder the examination of diagnosis of several endodontic conditions. Therefore, when CBCT is required in areas containing post materials, the clinician must be aware that these artifacts may alter the true diagnosis [8,19].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The presence of posts within the root canal generates artifacts, which may hinder the examination of diagnosis of several endodontic conditions. Therefore, when CBCT is required in areas containing post materials, the clinician must be aware that these artifacts may alter the true diagnosis [8,19].…”
Section: Discussionmentioning
confidence: 99%
“…The usage of a higher kVp and mAs improves image homogeneity and uniformity compared to the lower kVp and mAs [8]. Voxel size is directly related to the spatial resolution of an image; as voxel size decreases, resolution and detail increase.…”
Section: Introductionmentioning
confidence: 99%
“…The amount of radiation utilized to diagnose and sculpt image quality is the most crucial aspect of radiation exposure optimization [5]- [7]. The manufacturer, the government, and/or the user's experience are typically the sources of information used to regulate radiation levels or other criteria.…”
Section: Introductionmentioning
confidence: 99%
“…It is inappropriate to set the exposure parameter too high, but it is also unacceptable to set the exposure parameter too low [6]. Tube voltage (kVp), tube current (mA), and exposure time (s) are variables that might affect the quality of the image [7].…”
Section: Introductionmentioning
confidence: 99%