2021
DOI: 10.1109/jestpe.2020.3006267
|View full text |Cite
|
Sign up to set email alerts
|

The Impact of PV Panel Positioning and Degradation on the PV Inverter Lifetime and Reliability

Abstract: The PV inverter lifetime is affected by mission profiles, which include the solar irradiance and ambient temperature of the installation site. In previous research, the design for reliability approach has been used to evaluate the reliability of the PV inverter, where the solar irradiances have been measured on a fixed tilt and orientation angle. In most cases, the tilt is chosen to be the latitude angle and the orientation is facing south for maximum energy production throughout the year. However, the impact … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 41 publications
(15 citation statements)
references
References 40 publications
0
14
0
1
Order By: Relevance
“…At the same time, T j , ΔT j , and t on maintain a dynamic state, and the dynamic parameters need to be converted into equivalent static parameters, which can produce the same degradation effect on the device. Influenced by the change of saturation volt-age drop of the IGBT collector and the thermal load of each device, the average minimum junction temperature and junction temperature fluctuation of IGBT equivalent static parameters change according to the normal distributions of 5% and 0.66%, respectively [36].…”
Section: The Lcoe Of the Pv System Evaluation Processmentioning
confidence: 99%
“…At the same time, T j , ΔT j , and t on maintain a dynamic state, and the dynamic parameters need to be converted into equivalent static parameters, which can produce the same degradation effect on the device. Influenced by the change of saturation volt-age drop of the IGBT collector and the thermal load of each device, the average minimum junction temperature and junction temperature fluctuation of IGBT equivalent static parameters change according to the normal distributions of 5% and 0.66%, respectively [36].…”
Section: The Lcoe Of the Pv System Evaluation Processmentioning
confidence: 99%
“…Suhu normal pada panel surya adalah 25 ℃, pada suhu ini panel surya mampu beroprasi dengan optimal [4]. Rendahnya tegangan open circuit (Voc) yang dihasilkan sel surya disebabkan naiknya suhu pada panel dari suhu normalnya.…”
Section: A Faktor Kinerja Suhu Pada Modul Suryaunclassified
“…Power electronic converters are the main energy conversion system in a wide range of applications such as renewable energy systems, energy storage systems, smart and microgrid technologies, dc transmission and distribution systems, electric motor drives, and power supplies [1][2][3][4]. The widespread use of power electronic converters in various industries has made their reliable performance a top priority [5].…”
Section: Introductionmentioning